Size-distribution and mobility assessment of Hg and other risk elements in urban particulate matter and amended soils
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F12%3A00066801" target="_blank" >RIV/00216224:14310/12:00066801 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Size-distribution and mobility assessment of Hg and other risk elements in urban particulate matter and amended soils
Popis výsledku v původním jazyce
Urban particulate matter (PM) was collected in the most exposed area of Prague, close to highway, from filters of the air conditioning system in one large building. Finally four grain-size fractions: 0.507-0.119 mm, 0.119-0.063 mm, <0.063 mm and sub-fraction <0.025 mm were prepared after drying at the laboratory temperature. Several methods of destructive and non-destructive analysis were used to get elemental size-distributions: the Hg analyser AMA-254 (CV AAS), inductively coupled plasma - massspectrometry (ICP-MS), electrothermal atomic absorption spectrometry (ET AAS), instrumental neutron activation analysis (INAA), proton-induced X-ray emission (PIXE). Labile forms of toxicologically important analytes (Hg, As, Cd, Cr, Mn, Ni, Pb, Zn) weremeasured by AMA-254 and ICP-AES in 2M HNO3 extracted solutions.
Název v anglickém jazyce
Size-distribution and mobility assessment of Hg and other risk elements in urban particulate matter and amended soils
Popis výsledku anglicky
Urban particulate matter (PM) was collected in the most exposed area of Prague, close to highway, from filters of the air conditioning system in one large building. Finally four grain-size fractions: 0.507-0.119 mm, 0.119-0.063 mm, <0.063 mm and sub-fraction <0.025 mm were prepared after drying at the laboratory temperature. Several methods of destructive and non-destructive analysis were used to get elemental size-distributions: the Hg analyser AMA-254 (CV AAS), inductively coupled plasma - massspectrometry (ICP-MS), electrothermal atomic absorption spectrometry (ET AAS), instrumental neutron activation analysis (INAA), proton-induced X-ray emission (PIXE). Labile forms of toxicologically important analytes (Hg, As, Cd, Cr, Mn, Ni, Pb, Zn) weremeasured by AMA-254 and ICP-AES in 2M HNO3 extracted solutions.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP503%2F12%2F0682" target="_blank" >GAP503/12/0682: Transformace sloučenin rtuti půdní mikroflórou: možné využití pro bioremediační technologie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů