Simultaneous Detection of Purine Bases on Cu2O Nanoparticles Based Electrochemical Biosensor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F12%3A00069050" target="_blank" >RIV/00216224:14310/12:00069050 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Simultaneous Detection of Purine Bases on Cu2O Nanoparticles Based Electrochemical Biosensor
Popis výsledku v původním jazyce
Electrochemical determination of purine bases using screen-printed and spray-coated working electrodes on alumina substrate based on Cu2O nanoparticles is described in this work. Cu2O nanoparticles were synthetized using simple precipitation method and used for thick-film planar microelectrodes fabrication. The Cu2O nanoparticles were characterized by SEM and XRD analysis, which showed the presence of spherical aggregations with diameter of 1000 nm. Fabricated working electrodes based on these Cu2O nanoparticles were successfully used for adenine and guanine determination. The purine bases were detected indirectly by reduction of Cu ions. The current response of both electrodes types decreased with increasing adenine or guanine concentration. More sensitive detection was achieved with spray-coated electrodes with higher active surface area.
Název v anglickém jazyce
Simultaneous Detection of Purine Bases on Cu2O Nanoparticles Based Electrochemical Biosensor
Popis výsledku anglicky
Electrochemical determination of purine bases using screen-printed and spray-coated working electrodes on alumina substrate based on Cu2O nanoparticles is described in this work. Cu2O nanoparticles were synthetized using simple precipitation method and used for thick-film planar microelectrodes fabrication. The Cu2O nanoparticles were characterized by SEM and XRD analysis, which showed the presence of spherical aggregations with diameter of 1000 nm. Fabricated working electrodes based on these Cu2O nanoparticles were successfully used for adenine and guanine determination. The purine bases were detected indirectly by reduction of Cu ions. The current response of both electrodes types decreased with increasing adenine or guanine concentration. More sensitive detection was achieved with spray-coated electrodes with higher active surface area.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2012 IEEE SENSORS PROCEEDINGS
ISBN
9781457717666
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1208-1211
Název nakladatele
IEEE, 345 E 47TH ST, NEW YORK, NY 10017 USA
Místo vydání
New York
Místo konání akce
Taipei
Datum konání akce
1. 1. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000315671100295