Measurement of hydroxyl radicals in plasma pencil by laser induced fluorescence
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F13%3A00068906" target="_blank" >RIV/00216224:14310/13:00068906 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of hydroxyl radicals in plasma pencil by laser induced fluorescence
Popis výsledku v původním jazyce
Laser induced fluorescence was used for measurement of concentration of hydroxyl (OH) radicals in the plasma pencil, which is a radiofrequency plasma jet operated in argon at atmospheric pressure. The problematic of the rotational energy transfer, spectral overlap of the laser line and hydroxyl absorption line and saturation effects were treated. The method was calibrated by Rayleigh scattering on the ambient air. The concentration of hydroxyl radicals in the effluent of the plasma pencil was found to be in the order of 10 to 20 per cubic m. Dependence of hydroxyl concentration on argon flow rate and RF power delivered to the plasma were measured. Thy hydroxyl concentration was maximum at conditions, when the measurement point was close to the tip of the visible active discharge.
Název v anglickém jazyce
Measurement of hydroxyl radicals in plasma pencil by laser induced fluorescence
Popis výsledku anglicky
Laser induced fluorescence was used for measurement of concentration of hydroxyl (OH) radicals in the plasma pencil, which is a radiofrequency plasma jet operated in argon at atmospheric pressure. The problematic of the rotational energy transfer, spectral overlap of the laser line and hydroxyl absorption line and saturation effects were treated. The method was calibrated by Rayleigh scattering on the ambient air. The concentration of hydroxyl radicals in the effluent of the plasma pencil was found to be in the order of 10 to 20 per cubic m. Dependence of hydroxyl concentration on argon flow rate and RF power delivered to the plasma were measured. Thy hydroxyl concentration was maximum at conditions, when the measurement point was close to the tip of the visible active discharge.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
BL - Fyzika plasmatu a výboje v plynech
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0086" target="_blank" >ED2.1.00/03.0086: Regionální VaV centrum pro nízkonákladové plazmové a nanotechnologické povrchové úpravy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů