Determination of antibiotics (tetracyclines and sulfonamides) in biosolids by pressurized liquid extraction and liquid chromatography-tandem mass spectrometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F13%3A00080192" target="_blank" >RIV/00216224:14310/13:00080192 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.chroma.2013.05.014" target="_blank" >http://dx.doi.org/10.1016/j.chroma.2013.05.014</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2013.05.014" target="_blank" >10.1016/j.chroma.2013.05.014</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of antibiotics (tetracyclines and sulfonamides) in biosolids by pressurized liquid extraction and liquid chromatography-tandem mass spectrometry
Popis výsledku v původním jazyce
A robust and sensitive analytical method is developed to quantitatively determine tetracyclines and sulfonamides, two major antibiotic classes, in sewage sludge. The antibiotic agents, oxytetracycline, tetracycline, dioxycycline, chlorotetracycline, sulfathiazole, sulfapyridine, sulfamethazine and sulfamethoxazole, were extracted using pressurized liquid extraction (PLE) with citric acid at pH 3 and methanol (1:1 v/v). Clean-up of the extracts was performed by solid phase extraction (SPE) with hydrophilic-lipophilic balance cartridges. Identification and quantification of the compounds is by liquid chromatography-tandem mass spectrometry in multiple reaction monitoring (MRM) mode. High recoveries ranging from 90.4 to 99.9% for sulfonamides and 96.2 to100.9% for the tetracyclines are obtained. Method detection limits (MDLs) range from 0.6 to 4.2 ng/g for sulfonamides and 3.2 to 13 ng/g for tetracyclines.
Název v anglickém jazyce
Determination of antibiotics (tetracyclines and sulfonamides) in biosolids by pressurized liquid extraction and liquid chromatography-tandem mass spectrometry
Popis výsledku anglicky
A robust and sensitive analytical method is developed to quantitatively determine tetracyclines and sulfonamides, two major antibiotic classes, in sewage sludge. The antibiotic agents, oxytetracycline, tetracycline, dioxycycline, chlorotetracycline, sulfathiazole, sulfapyridine, sulfamethazine and sulfamethoxazole, were extracted using pressurized liquid extraction (PLE) with citric acid at pH 3 and methanol (1:1 v/v). Clean-up of the extracts was performed by solid phase extraction (SPE) with hydrophilic-lipophilic balance cartridges. Identification and quantification of the compounds is by liquid chromatography-tandem mass spectrometry in multiple reaction monitoring (MRM) mode. High recoveries ranging from 90.4 to 99.9% for sulfonamides and 96.2 to100.9% for the tetracyclines are obtained. Method detection limits (MDLs) range from 0.6 to 4.2 ng/g for sulfonamides and 3.2 to 13 ng/g for tetracyclines.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
—
Svazek periodika
1298
Číslo periodika v rámci svazku
july
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
68-75
Kód UT WoS článku
000321174700009
EID výsledku v databázi Scopus
—