A Pencil Graphite Electrode In Situ Modified by Monovalent Copper: a Promising Tool for the Determination of Methylxanthines
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F14%3A00075812" target="_blank" >RIV/00216224:14310/14:00075812 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68081707:_____/14:00435466
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elan.201400017" target="_blank" >http://dx.doi.org/10.1002/elan.201400017</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201400017" target="_blank" >10.1002/elan.201400017</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Pencil Graphite Electrode In Situ Modified by Monovalent Copper: a Promising Tool for the Determination of Methylxanthines
Popis výsledku v původním jazyce
A pencil graphite electrode (PeGE) exhibits a promising tool for the electrochemical analysis of xanthine (Xan) and its N-methyl derivatives (1-, 3-, 7- and 9-mXan). The changes in their level in blood, serum, urine, as products of purine catabolism, canindicate the development of some diseases. Sensitivity-enhanced voltammetric detection of mXans was achieved by forming of complex with Cu(I) and application of elimination procedure. The Cu(I)-mXan complex was identified by means of titration of electrochemically produced cuprous ions by mXan. Our approach enables separation of overlapped mXan oxidation signals. Based on the obtained results, we found that the effect of methyl group position on the xanthine skeleton was significant and it was also discussed.
Název v anglickém jazyce
A Pencil Graphite Electrode In Situ Modified by Monovalent Copper: a Promising Tool for the Determination of Methylxanthines
Popis výsledku anglicky
A pencil graphite electrode (PeGE) exhibits a promising tool for the electrochemical analysis of xanthine (Xan) and its N-methyl derivatives (1-, 3-, 7- and 9-mXan). The changes in their level in blood, serum, urine, as products of purine catabolism, canindicate the development of some diseases. Sensitivity-enhanced voltammetric detection of mXans was achieved by forming of complex with Cu(I) and application of elimination procedure. The Cu(I)-mXan complex was identified by means of titration of electrochemically produced cuprous ions by mXan. Our approach enables separation of overlapped mXan oxidation signals. Based on the obtained results, we found that the effect of methyl group position on the xanthine skeleton was significant and it was also discussed.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
10
Strana od-do
952-961
Kód UT WoS článku
000335997600009
EID výsledku v databázi Scopus
—