The use of flower-like gold nanoparticles in time-of-flight mass spectrometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F15%3A00082770" target="_blank" >RIV/00216224:14310/15:00082770 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The use of flower-like gold nanoparticles in time-of-flight mass spectrometry
Popis výsledku v původním jazyce
Various types of gold nanoparticles (AuNPs) represent promising tools in many biomedical applications.[1-2] Here we report the first use of flower-like (FL) AuNPs as a mediator enhancing ionization in mass spectrometry (MS) of biomolecules. The main objective was to determine the effect of FL AuNPs on the ionization of biomolecules by surface assisted and matrix assisted laser desorption ionization (SALDI and MALDI) MS with time-of-flight analyzer. FL AuNPs alone or combined with cyano-4-hydroxycinnamicacid (CHCA) for MS measurement of peptides (500-3 500 m/z) were used. The comparison with classical CHCA matrix shows that FL AuNPs increase the ionization (~ 7.5 x) of peptides both alone and in combination with CHCA matrix. For ionization of higher mass peptides/proteins and those from mouse embryonic fibroblast (MEF) cells, FL AuNPs combined with CHCA and sinapinic acid (SA) were used.
Název v anglickém jazyce
The use of flower-like gold nanoparticles in time-of-flight mass spectrometry
Popis výsledku anglicky
Various types of gold nanoparticles (AuNPs) represent promising tools in many biomedical applications.[1-2] Here we report the first use of flower-like (FL) AuNPs as a mediator enhancing ionization in mass spectrometry (MS) of biomolecules. The main objective was to determine the effect of FL AuNPs on the ionization of biomolecules by surface assisted and matrix assisted laser desorption ionization (SALDI and MALDI) MS with time-of-flight analyzer. FL AuNPs alone or combined with cyano-4-hydroxycinnamicacid (CHCA) for MS measurement of peptides (500-3 500 m/z) were used. The comparison with classical CHCA matrix shows that FL AuNPs increase the ionization (~ 7.5 x) of peptides both alone and in combination with CHCA matrix. For ionization of higher mass peptides/proteins and those from mouse embryonic fibroblast (MEF) cells, FL AuNPs combined with CHCA and sinapinic acid (SA) were used.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.20.0185" target="_blank" >EE2.3.20.0185: Centrum analýz a modelování tkání a orgánů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů