Simplified direct Kjeldahl method suitable as a primary reference procedure for the determination of total protein in reference materials used in clinical chemistry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F15%3A00108650" target="_blank" >RIV/00216224:14310/15:00108650 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.cskb.cz/res/file/KBM-pdf/2015/2015-4/KBM-4-2015-Chromy-188.pdf" target="_blank" >http://www.cskb.cz/res/file/KBM-pdf/2015/2015-4/KBM-4-2015-Chromy-188.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Simplified direct Kjeldahl method suitable as a primary reference procedure for the determination of total protein in reference materials used in clinical chemistry
Popis výsledku v původním jazyce
Chromý et al. found in 2009, that albumin-calibrated analysis of serum total protein with biuret reagent according to a candidate reference method developed by Doumas working group in 1981, provide results with unacceptable positive bias, caused namely by endogeneous serum bilirubin and lipids. They also found, that a simplest way to rectify this defect, is the use of serum and/or plasma-based protein standards, commutable with patients samples, which are certified by the Kjeldahl method. In our foregoing two articles, (Chromý et al., 2015, and Vinklárková et al., 2015), we reviewed Kjeldahl methods adopted by laboratory medicine, selected a direct analysis on washed protein precipitates with trichloroacetic acid and verified its preliminary analytical performance parameters. In this article, we describe a simplified Kjeldahl analysis with modified digestion flask, now directly connectable to accordingly adapted Parnas and Wagner distillation unit, and present its re-validation. Simplified Kjeldahl method is suggested as a standard operating procedure for total protein in reference materials used in clinical chemistry
Název v anglickém jazyce
Simplified direct Kjeldahl method suitable as a primary reference procedure for the determination of total protein in reference materials used in clinical chemistry
Popis výsledku anglicky
Chromý et al. found in 2009, that albumin-calibrated analysis of serum total protein with biuret reagent according to a candidate reference method developed by Doumas working group in 1981, provide results with unacceptable positive bias, caused namely by endogeneous serum bilirubin and lipids. They also found, that a simplest way to rectify this defect, is the use of serum and/or plasma-based protein standards, commutable with patients samples, which are certified by the Kjeldahl method. In our foregoing two articles, (Chromý et al., 2015, and Vinklárková et al., 2015), we reviewed Kjeldahl methods adopted by laboratory medicine, selected a direct analysis on washed protein precipitates with trichloroacetic acid and verified its preliminary analytical performance parameters. In this article, we describe a simplified Kjeldahl analysis with modified digestion flask, now directly connectable to accordingly adapted Parnas and Wagner distillation unit, and present its re-validation. Simplified Kjeldahl method is suggested as a standard operating procedure for total protein in reference materials used in clinical chemistry
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Klinická biochemie a metabolismus
ISSN
1210-7921
e-ISSN
—
Svazek periodika
23
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
188-192
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-84951044203