DIFFUSE COPLANAR SURFACE BARRIER DISCHARGE PRE-TREATMENT FOR IMPROVING COATING PROPERTIES
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F15%3A00114953" target="_blank" >RIV/00216224:14310/15:00114953 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14310/14:00077163
Výsledek na webu
<a href="http://nanocon2014.tanger.cz/files/proceedings/20/reports/3250.pdf" target="_blank" >http://nanocon2014.tanger.cz/files/proceedings/20/reports/3250.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
DIFFUSE COPLANAR SURFACE BARRIER DISCHARGE PRE-TREATMENT FOR IMPROVING COATING PROPERTIES
Popis výsledku v původním jazyce
Diffuse Coplanar Surface Barrier Discharge (DCSBD) was used to pre-treat surfaces of glass in order to remove adsorbed carbon contaminants and increase surface energy due to incorporation of oxygen-based polar functional groups. Afterwards, the plasma pre-treated glass surfaces were coated with TiO2 film deposited from sol-gel solution. Tribology measurements in coatings showed significant increase of adhesion of coatings deposited onto pre-treated surfaces, whereas coatings deposited onto untreated surfaces showed poor adhesion. Increase in adhesion is related with both cleaning and formation of functional groups. Cleaning, or removal of adsorbed carbon contaminants, led to uniform coating without any areas of surface energy instabilities, whereas functional groups provided necessary bonding between coating and surface.
Název v anglickém jazyce
DIFFUSE COPLANAR SURFACE BARRIER DISCHARGE PRE-TREATMENT FOR IMPROVING COATING PROPERTIES
Popis výsledku anglicky
Diffuse Coplanar Surface Barrier Discharge (DCSBD) was used to pre-treat surfaces of glass in order to remove adsorbed carbon contaminants and increase surface energy due to incorporation of oxygen-based polar functional groups. Afterwards, the plasma pre-treated glass surfaces were coated with TiO2 film deposited from sol-gel solution. Tribology measurements in coatings showed significant increase of adhesion of coatings deposited onto pre-treated surfaces, whereas coatings deposited onto untreated surfaces showed poor adhesion. Increase in adhesion is related with both cleaning and formation of functional groups. Cleaning, or removal of adsorbed carbon contaminants, led to uniform coating without any areas of surface energy instabilities, whereas functional groups provided necessary bonding between coating and surface.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
6th International Conference Nanocon 2014
ISBN
9788087294550
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
TANGER Ltd
Místo vydání
Ostrava
Místo konání akce
Brno
Datum konání akce
1. 1. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000350636300074