Copper Nanoparticle Modified Pencil Graphite Electrode for Electroanalysis of Adenine
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F16%3A00093646" target="_blank" >RIV/00216224:14310/16:00093646 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elan.201600237" target="_blank" >http://dx.doi.org/10.1002/elan.201600237</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201600237" target="_blank" >10.1002/elan.201600237</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Copper Nanoparticle Modified Pencil Graphite Electrode for Electroanalysis of Adenine
Popis výsledku v původním jazyce
A pencil graphite electrode (PeGE) modified with copper nanoparticles (CuNPs) was employed for sensitive electrochemical detection of adenine (Ade). The CuNPs were synthesized by the chemical reduction of copper (II) sulphate by borohydride in the presence of polyvinylpyrrolidone (PVP) and immobilized onto the electrode surface by means of physical adsorption. The cyclic voltammetry (CV) results illustrate that the CuNP-modified PeGE provides at least fivefold increase of Ade oxidation peaks compared to the bare PeGE. The detection limit in CV corresponds to value of 200nM. The accumulation of Ade through the complex with Cu (I) allows us to introduce the novel biosensor for the determination not only of adenine but also purines capable to form analogical Cu (I) complexes.
Název v anglickém jazyce
Copper Nanoparticle Modified Pencil Graphite Electrode for Electroanalysis of Adenine
Popis výsledku anglicky
A pencil graphite electrode (PeGE) modified with copper nanoparticles (CuNPs) was employed for sensitive electrochemical detection of adenine (Ade). The CuNPs were synthesized by the chemical reduction of copper (II) sulphate by borohydride in the presence of polyvinylpyrrolidone (PVP) and immobilized onto the electrode surface by means of physical adsorption. The cyclic voltammetry (CV) results illustrate that the CuNP-modified PeGE provides at least fivefold increase of Ade oxidation peaks compared to the bare PeGE. The detection limit in CV corresponds to value of 200nM. The accumulation of Ade through the complex with Cu (I) allows us to introduce the novel biosensor for the determination not only of adenine but also purines capable to form analogical Cu (I) complexes.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.30.0009" target="_blank" >EE2.3.30.0009: Zaměstnáním čerstvých absolventů doktorského studia k vědecké excelenci</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
28
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
7
Strana od-do
2834-2840
Kód UT WoS článku
000387891400027