Assessment of localized corrosion under simulated physiological conditions of magnesium samples with heterogeneous microstructure: Value of X-ray computed micro-tomography platform
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F16%3A00093780" target="_blank" >RIV/00216224:14310/16:00093780 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26620/16:PU116745
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.corsci.2015.12.009" target="_blank" >http://dx.doi.org/10.1016/j.corsci.2015.12.009</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.corsci.2015.12.009" target="_blank" >10.1016/j.corsci.2015.12.009</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assessment of localized corrosion under simulated physiological conditions of magnesium samples with heterogeneous microstructure: Value of X-ray computed micro-tomography platform
Popis výsledku v původním jazyce
Accurate assessment of magnesium degradation is crucial for the development of safe medical devices. X-ray computed microtomography is one of the methods that are recently used to evaluate the corrosion of magnesium. This work validates the potential of this method to discern the different corrosion rates of different surfaces of a magnesium coupon, representing a real advantage of this technique over other methodologies that only evaluate the overall corrosion behaviour. The results also show that magnesium corrodes faster in zones with high twin density and that its corrosion product formation varies in different simulated physiological fluids.
Název v anglickém jazyce
Assessment of localized corrosion under simulated physiological conditions of magnesium samples with heterogeneous microstructure: Value of X-ray computed micro-tomography platform
Popis výsledku anglicky
Accurate assessment of magnesium degradation is crucial for the development of safe medical devices. X-ray computed microtomography is one of the methods that are recently used to evaluate the corrosion of magnesium. This work validates the potential of this method to discern the different corrosion rates of different surfaces of a magnesium coupon, representing a real advantage of this technique over other methodologies that only evaluate the overall corrosion behaviour. The results also show that magnesium corrodes faster in zones with high twin density and that its corrosion product formation varies in different simulated physiological fluids.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Corrosion Science
ISSN
0010-938X
e-ISSN
—
Svazek periodika
104
Číslo periodika v rámci svazku
MAR
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
187-196
Kód UT WoS článku
000370457500019
EID výsledku v databázi Scopus
—