Miniaturized Biamperometric Detectors for Electrochemical Detection in Flowing Streams
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F17%3A00113891" target="_blank" >RIV/00216224:14310/17:00113891 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216275:25310/17:39911331
Výsledek na webu
<a href="http://onlinelibrary.wiley.com/doi/10.1002/elan.201700027/abstract" target="_blank" >http://onlinelibrary.wiley.com/doi/10.1002/elan.201700027/abstract</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201700027" target="_blank" >10.1002/elan.201700027</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Miniaturized Biamperometric Detectors for Electrochemical Detection in Flowing Streams
Popis výsledku v původním jazyce
Capillary electrochemical detectors with various configurations of electrodes were developed by inserting platinum multielectrodes (tetrodes) or platinum and carbon microelectrodes into the ending of capillaries. The biamperometric mode of detection, without the need of classical reference electrode, was employed in flow injection analysis of dopamine and norepinephrine selected as model samples. The influences of geometric shape of tetrodes, arrangement of electrodes and internal diameter of the capillary were studied thoroughly with respect to intensity of recorded currents. A novel pulse biamperometric technique was employed with the aim to enhance further the recorded currents of dopamine oxidation and to minimize the passivation of electrodes in mixed aqueous-organic carrier solution, which improved considerably the repeatability of measurements. Proposed low-cost microelectrode devices showed good prospects as detectors in simple and miniaturized flow systems, such as flow injection analysis and capillary high-performance liquid chromatography with monolithic columns.
Název v anglickém jazyce
Miniaturized Biamperometric Detectors for Electrochemical Detection in Flowing Streams
Popis výsledku anglicky
Capillary electrochemical detectors with various configurations of electrodes were developed by inserting platinum multielectrodes (tetrodes) or platinum and carbon microelectrodes into the ending of capillaries. The biamperometric mode of detection, without the need of classical reference electrode, was employed in flow injection analysis of dopamine and norepinephrine selected as model samples. The influences of geometric shape of tetrodes, arrangement of electrodes and internal diameter of the capillary were studied thoroughly with respect to intensity of recorded currents. A novel pulse biamperometric technique was employed with the aim to enhance further the recorded currents of dopamine oxidation and to minimize the passivation of electrodes in mixed aqueous-organic carrier solution, which improved considerably the repeatability of measurements. Proposed low-cost microelectrode devices showed good prospects as detectors in simple and miniaturized flow systems, such as flow injection analysis and capillary high-performance liquid chromatography with monolithic columns.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
1521-4109
Svazek periodika
29
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
4
Strana od-do
1670-1673
Kód UT WoS článku
000405310100002
EID výsledku v databázi Scopus
2-s2.0-85017406101