A method for analysis of marker persistent organic pollutants in low-volume plasma and serum samples using 96-well plate solid phase extraction
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F18%3A00102902" target="_blank" >RIV/00216224:14310/18:00102902 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S002196731830253X?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S002196731830253X?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2018.02.057" target="_blank" >10.1016/j.chroma.2018.02.057</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A method for analysis of marker persistent organic pollutants in low-volume plasma and serum samples using 96-well plate solid phase extraction
Popis výsledku v původním jazyce
The objective of this study was to develop and validate a 96-well plate solid phase extraction method for analysis of 23 lipophilic persistent organic pollutants (POPs) in low-volume plasma and serum samples which is applicable for biomonitoring and epidemiological studies. The analysis of selected markers for internal exposure: 16 polychlorinated biphenyls (PCBs), 5 organochlorine pesticides (OCPs), octachlorinated dibenzo-p-dioxin (OCDD), and polybrominated diphenylether 47 (BDE 47) was evaluated by comparing two SPE sorbents and GC-HRMS or GC-MS/MS detection. The final method extracted 23 POPs from 150 mu L of serum and plasma using a 96-well extraction plate containing 60 mg Oasis HLB sorbent per well prior to GC-HRMS magnetic sector analysis. The extraction method was applied to 40 plasma samples collected for an epidemiological study. The recovery of selected POPs ranged from 31% to 63% (n = 48), and detection limits ranged from 2.2 to 45 pg/mL for PCBs, 4.2 to 167 pg/mL for OCPs, 7.8 pg/mL for OCDD and 6.1 pg/mL for BDE 47. This method showed good precision with relative standard deviations of selected POP concentrations in quality control samples (n = 48) ranging from 11% to 25%. The trueness was determined with standard reference material serum (n = 48) and the deviation from certified values ranged from 1 to 27%. Of the 23 POPs analyzed, 18 were detected in 43% to 100% of plasma samples collected for the epidemiological study. The method showed good robustness with low inter-well plate variation (11-31%) determined by twelve 96-well plate extractions, and can extract 96 samples, including quality controls and procedural blanks in 2-3 days. Comparison with GC-MS/MS analysis showed that similar concentrations (within 0.5% to 30%) of most POPs could be obtained with GC-APCI-MS/MS. Larger deviations were observed for PCB 194 (60%) and trans-nonachlor (43%). The developed method produces accurate concentrations of low-level marker POPs in plasma and serum, providing a suitable high-throughput sample preparation procedure for biomonitoring and epidemiological studies involving large sample size and limited sample volume. GC-HRMS was chosen over GC-MS/MS, however the latter showed promising results, and could be used as an alternative to GC-HRMS analysis for most POPs.
Název v anglickém jazyce
A method for analysis of marker persistent organic pollutants in low-volume plasma and serum samples using 96-well plate solid phase extraction
Popis výsledku anglicky
The objective of this study was to develop and validate a 96-well plate solid phase extraction method for analysis of 23 lipophilic persistent organic pollutants (POPs) in low-volume plasma and serum samples which is applicable for biomonitoring and epidemiological studies. The analysis of selected markers for internal exposure: 16 polychlorinated biphenyls (PCBs), 5 organochlorine pesticides (OCPs), octachlorinated dibenzo-p-dioxin (OCDD), and polybrominated diphenylether 47 (BDE 47) was evaluated by comparing two SPE sorbents and GC-HRMS or GC-MS/MS detection. The final method extracted 23 POPs from 150 mu L of serum and plasma using a 96-well extraction plate containing 60 mg Oasis HLB sorbent per well prior to GC-HRMS magnetic sector analysis. The extraction method was applied to 40 plasma samples collected for an epidemiological study. The recovery of selected POPs ranged from 31% to 63% (n = 48), and detection limits ranged from 2.2 to 45 pg/mL for PCBs, 4.2 to 167 pg/mL for OCPs, 7.8 pg/mL for OCDD and 6.1 pg/mL for BDE 47. This method showed good precision with relative standard deviations of selected POP concentrations in quality control samples (n = 48) ranging from 11% to 25%. The trueness was determined with standard reference material serum (n = 48) and the deviation from certified values ranged from 1 to 27%. Of the 23 POPs analyzed, 18 were detected in 43% to 100% of plasma samples collected for the epidemiological study. The method showed good robustness with low inter-well plate variation (11-31%) determined by twelve 96-well plate extractions, and can extract 96 samples, including quality controls and procedural blanks in 2-3 days. Comparison with GC-MS/MS analysis showed that similar concentrations (within 0.5% to 30%) of most POPs could be obtained with GC-APCI-MS/MS. Larger deviations were observed for PCB 194 (60%) and trans-nonachlor (43%). The developed method produces accurate concentrations of low-level marker POPs in plasma and serum, providing a suitable high-throughput sample preparation procedure for biomonitoring and epidemiological studies involving large sample size and limited sample volume. GC-HRMS was chosen over GC-MS/MS, however the latter showed promising results, and could be used as an alternative to GC-HRMS analysis for most POPs.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/LM2015051" target="_blank" >LM2015051: Centrum pro výzkum toxických látek v prostředí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
—
Svazek periodika
1546
Číslo periodika v rámci svazku
April
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
10
Strana od-do
18-27
Kód UT WoS článku
000430766800003
EID výsledku v databázi Scopus
2-s2.0-85042642069