Exposure of Canadian electronic waste dismantlers to flame retardants

Identifikátory výsledku

  • Kód výsledku v IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F19%3A00110364" target="_blank" >RIV/00216224:14310/19:00110364 - isvavai.cz</a>

  • Výsledek na webu

    <a href="https://www.sciencedirect.com/science/article/pii/S0160412019301473?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0160412019301473?via%3Dihub</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.envint.2019.04.056" target="_blank" >10.1016/j.envint.2019.04.056</a>

Alternativní jazyky

  • Jazyk výsledku

    angličtina

  • Název v původním jazyce

    Exposure of Canadian electronic waste dismantlers to flame retardants

  • Popis výsledku v původním jazyce

    Exposure of e-waste workers to eight halogenated and five organophosphate ester flame retardant chemicals (FRs) was studied at a Canadian e-waste dismantling facility. FR concentrations were measured in air and dust samples collected at a central location and at four work benches over five-24 hour periods spanning two weeks. The highest concentrations in air from workbenches were of BDE-209 (median 156 ng m(-3)), followed by Tris(2-chloroethyl) phosphate (TCEP, median 59 ng m(-3)). Dust concentrations at the workbenches were higher than those measured at the central location, consistent with the release of contaminated dust during dismantling. Dust concentrations from the workbenches were also dominated by BDE-209 (median 96,300 ng g(-1)), followed by Triphenyl phosphate (TPhP, median 47,000 ng g(-1)). Most FRs were in coarse particles 5.6-18 mu m diameter and similar to 30% were in respirable particles (&lt; similar to 3 mu m). Exposure estimates indicated that dust ingestion accounted for 63% of total FR exposure; inhalation and dermal absorption contributed 35 and 2%, respectively. Some air and dust concentrations as well as some estimated exposures in this formal facility in a high-income country exceeded those from informal e-waste facilities located in low and middle income countries. Although there is demonstrated toxicity of some FRs, FR exposure in the e-waste industry has received minimal attention and occupational limits do not exist for most FRs.

  • Název v anglickém jazyce

    Exposure of Canadian electronic waste dismantlers to flame retardants

  • Popis výsledku anglicky

    Exposure of e-waste workers to eight halogenated and five organophosphate ester flame retardant chemicals (FRs) was studied at a Canadian e-waste dismantling facility. FR concentrations were measured in air and dust samples collected at a central location and at four work benches over five-24 hour periods spanning two weeks. The highest concentrations in air from workbenches were of BDE-209 (median 156 ng m(-3)), followed by Tris(2-chloroethyl) phosphate (TCEP, median 59 ng m(-3)). Dust concentrations at the workbenches were higher than those measured at the central location, consistent with the release of contaminated dust during dismantling. Dust concentrations from the workbenches were also dominated by BDE-209 (median 96,300 ng g(-1)), followed by Triphenyl phosphate (TPhP, median 47,000 ng g(-1)). Most FRs were in coarse particles 5.6-18 mu m diameter and similar to 30% were in respirable particles (&lt; similar to 3 mu m). Exposure estimates indicated that dust ingestion accounted for 63% of total FR exposure; inhalation and dermal absorption contributed 35 and 2%, respectively. Some air and dust concentrations as well as some estimated exposures in this formal facility in a high-income country exceeded those from informal e-waste facilities located in low and middle income countries. Although there is demonstrated toxicity of some FRs, FR exposure in the e-waste industry has received minimal attention and occupational limits do not exist for most FRs.

Klasifikace

  • Druh

    J<sub>imp</sub> - Článek v periodiku v databázi Web of Science

  • CEP obor

  • OECD FORD obor

    10511 - Environmental sciences (social aspects to be 5.7)

Návaznosti výsledku

  • Projekt

    <a href="/cs/project/LO1214" target="_blank" >LO1214: Centrum pro výzkum toxických látek v prostředí</a><br>

  • Návaznosti

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Ostatní

  • Rok uplatnění

    2019

  • Kód důvěrnosti údajů

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Údaje specifické pro druh výsledku

  • Název periodika

    Environment International

  • ISSN

    0160-4120

  • e-ISSN

    1873-6750

  • Svazek periodika

    129

  • Číslo periodika v rámci svazku

    August

  • Stát vydavatele periodika

    GB - Spojené království Velké Británie a Severního Irska

  • Počet stran výsledku

    10

  • Strana od-do

    95-104

  • Kód UT WoS článku

    000470239200012

  • EID výsledku v databázi Scopus

    2-s2.0-85065838801