Nanoparticle tag counting for tissue imaging using infrared laser ablation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14310%2F22%3A00128826" target="_blank" >RIV/00216224:14310/22:00128826 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Nanoparticle tag counting for tissue imaging using infrared laser ablation
Popis výsledku v původním jazyce
We report a new laser ablation technique employing a pulsed 2 940 nm laser and a simple ablation cell for digital mapping biomarkers in tissues using metal nanoparticle tags. Unlike the conventional laser ablation systems, where nanoparticles are ablated, we are able to desorb intact nanoparticles and count them. The method is demonstrated on monitoring proliferating cells in 3D aggregates of human colorectal carcinoma cells. Precise counting of the tags in each pixel generates sharp distribution maps of a proliferation biomarker in the tissue. A mass spectrometer detects up to 83% nanoparticles of a selected element with a single particle detection limit. Advantageously, the desorption of nanoparticles from regions outside the tissue is strongly suppressed.
Název v anglickém jazyce
Nanoparticle tag counting for tissue imaging using infrared laser ablation
Popis výsledku anglicky
We report a new laser ablation technique employing a pulsed 2 940 nm laser and a simple ablation cell for digital mapping biomarkers in tissues using metal nanoparticle tags. Unlike the conventional laser ablation systems, where nanoparticles are ablated, we are able to desorb intact nanoparticles and count them. The method is demonstrated on monitoring proliferating cells in 3D aggregates of human colorectal carcinoma cells. Precise counting of the tags in each pixel generates sharp distribution maps of a proliferation biomarker in the tissue. A mass spectrometer detects up to 83% nanoparticles of a selected element with a single particle detection limit. Advantageously, the desorption of nanoparticles from regions outside the tissue is strongly suppressed.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů