Neutron and Gamma Spectrometry in the Research Reactor LR-0
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14330%2F09%3A00067200" target="_blank" >RIV/00216224:14330/09:00067200 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/ANIMMA.2009.5503799" target="_blank" >http://dx.doi.org/10.1109/ANIMMA.2009.5503799</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ANIMMA.2009.5503799" target="_blank" >10.1109/ANIMMA.2009.5503799</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Neutron and Gamma Spectrometry in the Research Reactor LR-0
Popis výsledku v původním jazyce
Complex measurement system for full-scale VVER models (mock-ups), created in the research reactor LR-0, is discussed. Fast neutron (energy from 0.5 to 10 MeV) and gamma spectra are measured in several representative points of mock-ups by two-parameter spectrometer with cylindrical stilbene scintillation detectors. Measurements in the thermal and epithermal neutron region are carried out with activation method using broad set of activation monitors and with 3He(n,p) counter. Activation measurements withthreshold fast neutron detectors enlarge also proton-recoil spectra measurements, such measurements are carried out especially in cases, when spectrometer cannot be put in the necessary position. The core fission rate distribution is obtained by means ofgamma-scanning of fuel pins. The low noise precise power (flux density) monitoring system, independent of operation control system, was developed in the LR-0 reactor for mock-up experiments.
Název v anglickém jazyce
Neutron and Gamma Spectrometry in the Research Reactor LR-0
Popis výsledku anglicky
Complex measurement system for full-scale VVER models (mock-ups), created in the research reactor LR-0, is discussed. Fast neutron (energy from 0.5 to 10 MeV) and gamma spectra are measured in several representative points of mock-ups by two-parameter spectrometer with cylindrical stilbene scintillation detectors. Measurements in the thermal and epithermal neutron region are carried out with activation method using broad set of activation monitors and with 3He(n,p) counter. Activation measurements withthreshold fast neutron detectors enlarge also proton-recoil spectra measurements, such measurements are carried out especially in cases, when spectrometer cannot be put in the necessary position. The core fission rate distribution is obtained by means ofgamma-scanning of fuel pins. The low noise precise power (flux density) monitoring system, independent of operation control system, was developed in the LR-0 reactor for mock-up experiments.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
IN - Informatika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA)
ISBN
9781424452088
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
137-1-137-7
Název nakladatele
Université de Provence
Místo vydání
Marseille
Místo konání akce
Marseille
Datum konání akce
1. 1. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce