Digital Multiparameter System for Characterizing the Neutron-Gamma Field in the LR-O Experimental Reactor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14610%2F07%3A00042531" target="_blank" >RIV/00216224:14610/07:00042531 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Digital Multiparameter System for Characterizing the Neutron-Gamma Field in the LR-O Experimental Reactor
Popis výsledku v původním jazyce
The present paper points toward the possibility of reducing the proportion of analog processing in an apparatus employed to measure the neutron and photon energy spectra. The digitization of the detector output pulses makes it possible to process the information contained in the pulses either instantaneously or subsequently. The present paper deals with the method of digitizing the leading edge of the pulses generated by a stilbene organic scintillator or an NE-213 scintillator. The neutron versus gammadiscrimination can be carried out on the basis of the pulse leading edge duration. Coping with this task requires a digitizer featuring quite a high sampling frequency, which must exceed 1 GHz. The requirements for the amplitude digitization frequency are less severe, however, the amplitude resolution must be better than 8 bits. Both of the above requirements can be met with present-day components. The digitization is expected to result in reducing the apparatus size and improving its f
Název v anglickém jazyce
Digital Multiparameter System for Characterizing the Neutron-Gamma Field in the LR-O Experimental Reactor
Popis výsledku anglicky
The present paper points toward the possibility of reducing the proportion of analog processing in an apparatus employed to measure the neutron and photon energy spectra. The digitization of the detector output pulses makes it possible to process the information contained in the pulses either instantaneously or subsequently. The present paper deals with the method of digitizing the leading edge of the pulses generated by a stilbene organic scintillator or an NE-213 scintillator. The neutron versus gammadiscrimination can be carried out on the basis of the pulse leading edge duration. Coping with this task requires a digitizer featuring quite a high sampling frequency, which must exceed 1 GHz. The requirements for the amplitude digitization frequency are less severe, however, the amplitude resolution must be better than 8 bits. Both of the above requirements can be met with present-day components. The digitization is expected to result in reducing the apparatus size and improving its f
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
IN - Informatika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of ASTM International (JAI)
ISSN
1546-962X
e-ISSN
—
Svazek periodika
4
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—