Novel laser desorption sample introduction methods for inductively coupled plasma mass spectrometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F11%3A00050177" target="_blank" >RIV/00216224:14740/11:00050177 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Novel laser desorption sample introduction methods for inductively coupled plasma mass spectrometry
Popis výsledku v původním jazyce
New methods for determination of trace elements in submicroliter sample volumes, substrate-assisted laser desorption (SALD) and laser diode thermal vaporization (LDTV) inductively-coupled plasma mass spectrometry (ICP-MS) are presented. In summary, the both SALD and LDTV ICP-MS are suitable for quantitative elemental analysis of low volume samples (typically 100-500 nL) and represent an alternative to nebulizers. Potential advantages are also easy archiving, transportation, option of prearranged calibration sets on substrate and high throughput due to minimization of memory effects. In addition, biological samples, such as metalloproteins or metal complexes can be analyzed in multiple detection modes (SALD ICP-MS, MALDI-MS or fluorescence) from the same sample, which can provide supplementary information, e.g. protein mass or identity.
Název v anglickém jazyce
Novel laser desorption sample introduction methods for inductively coupled plasma mass spectrometry
Popis výsledku anglicky
New methods for determination of trace elements in submicroliter sample volumes, substrate-assisted laser desorption (SALD) and laser diode thermal vaporization (LDTV) inductively-coupled plasma mass spectrometry (ICP-MS) are presented. In summary, the both SALD and LDTV ICP-MS are suitable for quantitative elemental analysis of low volume samples (typically 100-500 nL) and represent an alternative to nebulizers. Potential advantages are also easy archiving, transportation, option of prearranged calibration sets on substrate and high throughput due to minimization of memory effects. In addition, biological samples, such as metalloproteins or metal complexes can be analyzed in multiple detection modes (SALD ICP-MS, MALDI-MS or fluorescence) from the same sample, which can provide supplementary information, e.g. protein mass or identity.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů