Investigation of Matrix Deposition Techniques for High Throughput MALDI MS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F11%3A00050182" target="_blank" >RIV/00216224:14740/11:00050182 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Investigation of Matrix Deposition Techniques for High Throughput MALDI MS
Popis výsledku v původním jazyce
Matrix assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) is an emerging technique with an immense biochemical and pharmaceutical potential, which possesses ability to show spatial distribution of specific compounds in tissues. The crucial step of MALDI-MSI experiment is matrix deposition. The MALDI matrix together with rhodamine B labeled angiotensin I was deposited on sample MALDI plate by three different approaches. By electrospray, spin-coating and piezoelectric nano-spotter.The homogeneity of deposited samples was studied under microscope by observing simple optical image and by observing fluorescence image after irradiating the sample with 532 nm laser. Optical image was compared with the MSI generated map of peptide distribution along the samples. To measure spatial distribution of selected peptides, a laboratory-built high-throughput axial time-of-flight (TOF) mass spectrometer with 2 kHz 355 nm Nd:YAG laser was used.
Název v anglickém jazyce
Investigation of Matrix Deposition Techniques for High Throughput MALDI MS
Popis výsledku anglicky
Matrix assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) is an emerging technique with an immense biochemical and pharmaceutical potential, which possesses ability to show spatial distribution of specific compounds in tissues. The crucial step of MALDI-MSI experiment is matrix deposition. The MALDI matrix together with rhodamine B labeled angiotensin I was deposited on sample MALDI plate by three different approaches. By electrospray, spin-coating and piezoelectric nano-spotter.The homogeneity of deposited samples was studied under microscope by observing simple optical image and by observing fluorescence image after irradiating the sample with 532 nm laser. Optical image was compared with the MSI generated map of peptide distribution along the samples. To measure spatial distribution of selected peptides, a laboratory-built high-throughput axial time-of-flight (TOF) mass spectrometer with 2 kHz 355 nm Nd:YAG laser was used.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů