Diode laser thermal vaporization inductively coupled plasma mass spectrometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F12%3A00057290" target="_blank" >RIV/00216224:14740/12:00057290 - isvavai.cz</a>
Výsledek na webu
<a href="http://pubs.acs.org/journals/ancham/index.html" target="_blank" >http://pubs.acs.org/journals/ancham/index.html</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1021/ac202884m" target="_blank" >10.1021/ac202884m</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Diode laser thermal vaporization inductively coupled plasma mass spectrometry
Popis výsledku v původním jazyce
An approach of sample introduction for inductively coupled mass spectrometry (ICPMS), diode laser thermal vaporization (DLTV) is described. The method allows quantitative determination of metals in submicroliter volumes of liquid samples. Laser power issufficient to induce pyrolysis of a suitable substrate with the deposited sample leading to aerosol generation. Unlike existing sample introduction systems based on laser ablation, it uses a NIR diode laser rather than an expensive high-energy pulsed laser. For certain elements, this sample introduction technique may serve as an alternative to solution analysis with conventional nebulizers. Using a prearranged calibration set, DLTV ICPMS provides rapid and reproducible sample analysis (RSD 10%). Samplepreparation is fast and simple, and the prepared samples can easily be archived and transported. The limits of detection for Co, Ni, Zn, Mo, Cd, Sn, and Pb deposited on the preprinted paper were found to be in the range of 0.4?30 pg.
Název v anglickém jazyce
Diode laser thermal vaporization inductively coupled plasma mass spectrometry
Popis výsledku anglicky
An approach of sample introduction for inductively coupled mass spectrometry (ICPMS), diode laser thermal vaporization (DLTV) is described. The method allows quantitative determination of metals in submicroliter volumes of liquid samples. Laser power issufficient to induce pyrolysis of a suitable substrate with the deposited sample leading to aerosol generation. Unlike existing sample introduction systems based on laser ablation, it uses a NIR diode laser rather than an expensive high-energy pulsed laser. For certain elements, this sample introduction technique may serve as an alternative to solution analysis with conventional nebulizers. Using a prearranged calibration set, DLTV ICPMS provides rapid and reproducible sample analysis (RSD 10%). Samplepreparation is fast and simple, and the prepared samples can easily be archived and transported. The limits of detection for Co, Ni, Zn, Mo, Cd, Sn, and Pb deposited on the preprinted paper were found to be in the range of 0.4?30 pg.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Chemistry
ISSN
0003-2700
e-ISSN
—
Svazek periodika
84
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
2268-2274
Kód UT WoS článku
000301021400026