Extending the linear range of the SALDI-MS analyses using the internal standard technique
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F12%3A00057867" target="_blank" >RIV/00216224:14740/12:00057867 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Extending the linear range of the SALDI-MS analyses using the internal standard technique
Popis výsledku v původním jazyce
Surface-assisted laser desorption/ionization mass spectrometry (SALDI MS) employing gold nanoparticles (Au NPs) has been presented as a useful method for the both qualitative and quantitative analysis of low molecular weight analytes. Besides the well-known benefit, such as the improvement in the analysis precision, the use of an internal standard was observed to significantly extend the linear range of SALDI MS. Without the use of the internal standard, the linear range is presumably limited by the saturation of the Au NP surface where the desorption process takes place: at higher analyte concentration, an imperfect, multilayer assembly is formed leading to inefficient desorption and/or ionization and thus to reduced linearity and poor reproducibility.
Název v anglickém jazyce
Extending the linear range of the SALDI-MS analyses using the internal standard technique
Popis výsledku anglicky
Surface-assisted laser desorption/ionization mass spectrometry (SALDI MS) employing gold nanoparticles (Au NPs) has been presented as a useful method for the both qualitative and quantitative analysis of low molecular weight analytes. Besides the well-known benefit, such as the improvement in the analysis precision, the use of an internal standard was observed to significantly extend the linear range of SALDI MS. Without the use of the internal standard, the linear range is presumably limited by the saturation of the Au NP surface where the desorption process takes place: at higher analyte concentration, an imperfect, multilayer assembly is formed leading to inefficient desorption and/or ionization and thus to reduced linearity and poor reproducibility.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů