DEVELOPMENT OF THE MOBILE STAND-OFF LASER-INDUCED BREAKDOWN SPECTROSCOPY SETUP
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F13%3A00070565" target="_blank" >RIV/00216224:14740/13:00070565 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
DEVELOPMENT OF THE MOBILE STAND-OFF LASER-INDUCED BREAKDOWN SPECTROSCOPY SETUP
Popis výsledku v původním jazyce
Here we present the development of the Laser Induced Breakdown Spectroscopy (LIBS) setup in the Stand-Off mobile configuration. The setup with potential applications mainly in the field of archeology, geology and metal industry enables to move the LIBS technique and its advantages out of the laboratory. The stand-Off configuration utilizes refracting telescope to focus high energy laser pulse onto the sample surface in the given distance (~ 6 m) and reflecting telescope to remotely collect the radiationof the induced plasma. The process of the development is described from the first table-top testing setup to the present fully mobile setup, together with the design intentions for the near future. Some of the spectra obtained from analysis of differentmaterials in the distance of 6.2 m will be shown to demonstrate the performance of the current setup.
Název v anglickém jazyce
DEVELOPMENT OF THE MOBILE STAND-OFF LASER-INDUCED BREAKDOWN SPECTROSCOPY SETUP
Popis výsledku anglicky
Here we present the development of the Laser Induced Breakdown Spectroscopy (LIBS) setup in the Stand-Off mobile configuration. The setup with potential applications mainly in the field of archeology, geology and metal industry enables to move the LIBS technique and its advantages out of the laboratory. The stand-Off configuration utilizes refracting telescope to focus high energy laser pulse onto the sample surface in the given distance (~ 6 m) and reflecting telescope to remotely collect the radiationof the induced plasma. The process of the development is described from the first table-top testing setup to the present fully mobile setup, together with the design intentions for the near future. Some of the spectra obtained from analysis of differentmaterials in the distance of 6.2 m will be shown to demonstrate the performance of the current setup.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.1.00%2F02.0068" target="_blank" >ED1.1.00/02.0068: CEITEC - central european institute of technology</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů