Diode laser thermal vaporisation inductively coupled plasma mass spectrometry of cobalamins
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F14%3A00073491" target="_blank" >RIV/00216224:14740/14:00073491 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Diode laser thermal vaporisation inductively coupled plasma mass spectrometry of cobalamins
Popis výsledku v původním jazyce
A diode laser thermal vaporization (DLTV) is a sample introduction technique to inductively coupled plasma (ICP), which presents a low-cost alternative to the commercial laser-ablation systems and nebulizers The determination of cobalamin derivatives isof great importance in pharmaceutical analysis. Here we present determination of cobalamins using DLTV ICP MS. Furthermore, the coupling of sensitive DLTV ICP MS with the TLC separation is investigated. Ascending thin layer chromatography (TLC) separation of cobalamins was performed on cellulose ? aluminum sheets at ambient temperature in the dark, eluting with solution of n-butanol:ethanol:water (10:3:7). The black ink line was printed over the evolved chromatography sheet, which was used as the substrate for the DLTV technique. The TLC chromatogram was scanned in a simple laboratory-built chamber with the diode laser.
Název v anglickém jazyce
Diode laser thermal vaporisation inductively coupled plasma mass spectrometry of cobalamins
Popis výsledku anglicky
A diode laser thermal vaporization (DLTV) is a sample introduction technique to inductively coupled plasma (ICP), which presents a low-cost alternative to the commercial laser-ablation systems and nebulizers The determination of cobalamin derivatives isof great importance in pharmaceutical analysis. Here we present determination of cobalamins using DLTV ICP MS. Furthermore, the coupling of sensitive DLTV ICP MS with the TLC separation is investigated. Ascending thin layer chromatography (TLC) separation of cobalamins was performed on cellulose ? aluminum sheets at ambient temperature in the dark, eluting with solution of n-butanol:ethanol:water (10:3:7). The black ink line was printed over the evolved chromatography sheet, which was used as the substrate for the DLTV technique. The TLC chromatogram was scanned in a simple laboratory-built chamber with the diode laser.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů