Cerebrospinal fluid oligoclonal IgM test in routine practice: Comparison with quantitative assessment of intrathecal IgM synthesis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A90128%2F20%3A00140072" target="_blank" >RIV/00216224:90128/20:00140072 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61988987:17110/20:A21026QG RIV/00843989:_____/20:E0108434
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0009898120302187?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0009898120302187?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.cca.2020.05.021" target="_blank" >10.1016/j.cca.2020.05.021</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Cerebrospinal fluid oligoclonal IgM test in routine practice: Comparison with quantitative assessment of intrathecal IgM synthesis
Popis výsledku v původním jazyce
Background: Intrathecal IgM synthesis demonstrated either as cerebrospinal fluid (CSF)-restricted oligoclonal (o-) IgM bands or calculated using various formulas has been linked to more aggressive multiple sclerosis (MS) course. However, the proportion of MS patients showing intrathecal IgM synthesis varies largely between studies. We aimed to explore the relation between different formulas and results of o-IgM, and to assess the frequency of o-IgM bands in an unselected series of samples. Methods: 432 samples were analyzed for o-IgM, o-IgG and quantitative measures of IgM and IgG synthesis. IgM index and formulas of Reiber, Auer and Ohman were compared to the result of the o-IgM test. Results: At the cut-off commonly used, the non-linear formulas for intrathecal synthesis were specific (> 94%) but rather insensitive (< 40% even at a cut-off of 4 CSF-restricted bands) compared to o-IgM. No significant difference was noted in the performance of different formulas. At a cut-off of 4 bands, 61% of MS patients, but none of the controls were positive for o-IgM. Conclusions: Formulas for intrathecal IgM synthesis are insensitive compared to o-IgM. We propose to evaluate samples with 2 or 3 extra-CSF IgM bands as borderline and only samples with 4 or more as definitely positive.
Název v anglickém jazyce
Cerebrospinal fluid oligoclonal IgM test in routine practice: Comparison with quantitative assessment of intrathecal IgM synthesis
Popis výsledku anglicky
Background: Intrathecal IgM synthesis demonstrated either as cerebrospinal fluid (CSF)-restricted oligoclonal (o-) IgM bands or calculated using various formulas has been linked to more aggressive multiple sclerosis (MS) course. However, the proportion of MS patients showing intrathecal IgM synthesis varies largely between studies. We aimed to explore the relation between different formulas and results of o-IgM, and to assess the frequency of o-IgM bands in an unselected series of samples. Methods: 432 samples were analyzed for o-IgM, o-IgG and quantitative measures of IgM and IgG synthesis. IgM index and formulas of Reiber, Auer and Ohman were compared to the result of the o-IgM test. Results: At the cut-off commonly used, the non-linear formulas for intrathecal synthesis were specific (> 94%) but rather insensitive (< 40% even at a cut-off of 4 CSF-restricted bands) compared to o-IgM. No significant difference was noted in the performance of different formulas. At a cut-off of 4 bands, 61% of MS patients, but none of the controls were positive for o-IgM. Conclusions: Formulas for intrathecal IgM synthesis are insensitive compared to o-IgM. We propose to evaluate samples with 2 or 3 extra-CSF IgM bands as borderline and only samples with 4 or more as definitely positive.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
30230 - Other clinical medicine subjects
Návaznosti výsledku
Projekt
—
Návaznosti
—
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Clinica Chimica Acta
ISSN
0009-8981
e-ISSN
—
Svazek periodika
508
Číslo periodika v rámci svazku
NA
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
9
Strana od-do
137-145
Kód UT WoS článku
000549228300021
EID výsledku v databázi Scopus
—