Extrakce epitopů - nástroj ke screeningu potencionálních peptidů vhodných pro vakcínu, za použití proteolytického magnetického reaktoru kombinovaného s FT-ICR MS.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F05%3A00002641" target="_blank" >RIV/00216275:25310/05:00002641 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Epitope extraction technique using a proteolytic microreactor combined with FTICR-MS as a tool for high-throughput screening of potential vaccine lead proteins
Popis výsledku v původním jazyce
Epitope extraction technique is based on the specific digestion of a target protein followed by immunoaffinity isolation of a specific recognition peptide. This technique, in combination with mass spectrometry, has been efficiently used for epitope identification. The major goal of this work was to utilize newly developed enzyme and immunoaffinity magnetic reactors for the epitope extraction procedure and confirm the efficiency of this improved system for epitope screening of proteins. Alginic acid-coated magnetite microparticles with immobilized TPCK-trypsin provided high working efficiency with low non-specific adsorption, digestion time in minutes and low frequency of missed cleavages. The sensitivity and specificity of tryptic fragmentation of thebeta-amyloid-peptide Abeta (1-40) as a model polypeptide was confirmed by Fourier-transform ion cyclotron resonance mass spectrometry analysis. The Sepharose reactor or immunoaffinity magnetic reactors, both with anti-amyloid-beta monoclo
Název v anglickém jazyce
Epitope extraction technique using a proteolytic microreactor combined with FTICR-MS as a tool for high-throughput screening of potential vaccine lead proteins
Popis výsledku anglicky
Epitope extraction technique is based on the specific digestion of a target protein followed by immunoaffinity isolation of a specific recognition peptide. This technique, in combination with mass spectrometry, has been efficiently used for epitope identification. The major goal of this work was to utilize newly developed enzyme and immunoaffinity magnetic reactors for the epitope extraction procedure and confirm the efficiency of this improved system for epitope screening of proteins. Alginic acid-coated magnetite microparticles with immobilized TPCK-trypsin provided high working efficiency with low non-specific adsorption, digestion time in minutes and low frequency of missed cleavages. The sensitivity and specificity of tryptic fragmentation of thebeta-amyloid-peptide Abeta (1-40) as a model polypeptide was confirmed by Fourier-transform ion cyclotron resonance mass spectrometry analysis. The Sepharose reactor or immunoaffinity magnetic reactors, both with anti-amyloid-beta monoclo
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA203%2F05%2F0241" target="_blank" >GA203/05/0241: Vývoj bioafinitních reaktorů pro detekci a analýzu epitopů s imunogenním nebo alergogenním potenciálem pomocí mikročipových analyzátorů</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European Journal of Mass Spectrometry
ISSN
1469-0667
e-ISSN
—
Svazek periodika
11
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
489-495
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—