Testování mikrofiltračního zařízení s modulem s dutými vlákny
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F05%3A00002806" target="_blank" >RIV/00216275:25310/05:00002806 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Dead-end Hollow Fibre Microfiltration Module Testing
Popis výsledku v původním jazyce
In this work, the hollow fibre membrane module designed for dead-end operations was tested. The hollow fibre cartridge operated from the outside to the inside during a filtration process, the membrane used was the polypropylene microfiltration membrane.Process characteristic measurements were carried out based on the pure water flux measurements. Next, the set of experiments dealing with microfiltration of model solutions was performed at different conditions. The influence of process parameters on thepermeate flux was studied aimed mainly at the membrane fouling preclusion.The set of experiments for "sustainable" flux determination was performed for water suspension of A-zeolite. From the results it followed that the fouling of the membrane was negligible for concentration of zeolite less than 3 kg.m-3. A simple mathematical model of the process was suggested and experimentally verified.
Název v anglickém jazyce
The Dead-end Hollow Fibre Microfiltration Module Testing
Popis výsledku anglicky
In this work, the hollow fibre membrane module designed for dead-end operations was tested. The hollow fibre cartridge operated from the outside to the inside during a filtration process, the membrane used was the polypropylene microfiltration membrane.Process characteristic measurements were carried out based on the pure water flux measurements. Next, the set of experiments dealing with microfiltration of model solutions was performed at different conditions. The influence of process parameters on thepermeate flux was studied aimed mainly at the membrane fouling preclusion.The set of experiments for "sustainable" flux determination was performed for water suspension of A-zeolite. From the results it followed that the fouling of the membrane was negligible for concentration of zeolite less than 3 kg.m-3. A simple mathematical model of the process was suggested and experimentally verified.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scientific Papers of the University of Pardubice, Series A, Faculty of Chemical Technology
ISSN
1211-5541
e-ISSN
—
Svazek periodika
—
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
11
Strana od-do
209-219