Aplikace LC-MSD a GC-ECD technik v analýze povýbuchových zbytků výbušin s obsahem 1,3,5-trinitroso-1,3,5-triazinanu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F05%3A00003132" target="_blank" >RIV/00216275:25310/05:00003132 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Application of LC-MSD and GC-ECD Techniques in the Analysis of Post-Explosion Residuem of Explosives with Kontent of 1,3,5-Trinitroso-1,3,5-triazinane
Popis výsledku v původním jazyce
The paper deals with possible applications of the connection of liquid chromatography with atmospheric pressure chemical ionization (APCI) mass spectrometry (Agilent 1100 series LS-MSD system) and gas chromatography with electron capture detector (GC-ECD) in the analysis of some common available or improvised explosives. The analysis of selected types of individual explosives, 2,4,6-trinitrotoluene (TNT), 1,3,5-trinitroso-1,3,5-triazinane (TMTA) and analysis of their mixtures (TNT/TMTA and RDX/TMTA) intheir post explosion residues on the basis of generated characteristic mass spectra by using LC-MSD system is the aim of this work. Post explosion analysis of TMTA and its explosive mixtures can be similarly complicated, like that of the well-known plastic explosive on the basis of pentaerythritol tetranitrate, Semtex-1A.
Název v anglickém jazyce
Application of LC-MSD and GC-ECD Techniques in the Analysis of Post-Explosion Residuem of Explosives with Kontent of 1,3,5-Trinitroso-1,3,5-triazinane
Popis výsledku anglicky
The paper deals with possible applications of the connection of liquid chromatography with atmospheric pressure chemical ionization (APCI) mass spectrometry (Agilent 1100 series LS-MSD system) and gas chromatography with electron capture detector (GC-ECD) in the analysis of some common available or improvised explosives. The analysis of selected types of individual explosives, 2,4,6-trinitrotoluene (TNT), 1,3,5-trinitroso-1,3,5-triazinane (TMTA) and analysis of their mixtures (TNT/TMTA and RDX/TMTA) intheir post explosion residues on the basis of generated characteristic mass spectra by using LC-MSD system is the aim of this work. Post explosion analysis of TMTA and its explosive mixtures can be similarly complicated, like that of the well-known plastic explosive on the basis of pentaerythritol tetranitrate, Semtex-1A.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CC - Organická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Central European Journal of Energetic Materials
ISSN
1733-7178
e-ISSN
—
Svazek periodika
2
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
12
Strana od-do
85-96
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—