The simultaneous determination of ubiquinol-10 and ubiquinone-10 in human plasma using HPLC with electrochemical detection
Popis výsledku v původním jazyce
Coenzyme Q10 is an important endogenous lipid-soluble antioxidant. Ubiquinol-10, the reduced form of coenzyme Q10 protects cells from oxidative damage. The oxidized form of coenzyme Q10 is known as ubiqinone-10. The ubiquinol-10/ ubiquinone-10 ratio maybe used as a marker for oxidative damage. The aim was to develop a HPLC method for the simultaneous determination of ubiquinol 10 and ubiquinone 10 in human plasma. Plasma for analysis was collected into vacutainer tubes containing EDTA. Tubes were centrifuged and extracted with hexane and methanol. Sample was injected onto 125 x 4 mm RP-C18 column (Purospher, 5 um; Merck). The mobile phase consisted of methanol-2-propanol-sodium acetate. We had filtered this mobile phase through a 0.45 um nylon filterand than deaerated before use. The flow rate was 1 ml/min and temperature was set to 37°C. We detected coenzyme Q10 with ESA Coulochem II 5100A electrochemical detector. After separation, the components passed the conditioning cell (-600
Název v anglickém jazyce
The simultaneous determination of ubiquinol-10 and ubiquinone-10 in human plasma using HPLC with electrochemical detection
Popis výsledku anglicky
Coenzyme Q10 is an important endogenous lipid-soluble antioxidant. Ubiquinol-10, the reduced form of coenzyme Q10 protects cells from oxidative damage. The oxidized form of coenzyme Q10 is known as ubiqinone-10. The ubiquinol-10/ ubiquinone-10 ratio maybe used as a marker for oxidative damage. The aim was to develop a HPLC method for the simultaneous determination of ubiquinol 10 and ubiquinone 10 in human plasma. Plasma for analysis was collected into vacutainer tubes containing EDTA. Tubes were centrifuged and extracted with hexane and methanol. Sample was injected onto 125 x 4 mm RP-C18 column (Purospher, 5 um; Merck). The mobile phase consisted of methanol-2-propanol-sodium acetate. We had filtered this mobile phase through a 0.45 um nylon filterand than deaerated before use. The flow rate was 1 ml/min and temperature was set to 37°C. We detected coenzyme Q10 with ESA Coulochem II 5100A electrochemical detector. After separation, the components passed the conditioning cell (-600
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Clin. Chim. Acta suppl.
ISBN
0009-8981
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
227
Název nakladatele
Elsevier
Místo vydání
UK
Místo konání akce
Glasgow, Skotsko
Datum konání akce
8. 5. 2005
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—