Limity přesnosti a intervalové odhady v kalibraci 1-hydroxypyrenu v moči a hexachlorbenzenu ve vodě aplikací regresního tripletu na chromatografická data
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F08%3A00006024" target="_blank" >RIV/00216275:25310/08:00006024 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Precision Limits and Interval Estimation in the Calibration of 1-hydroxypyrene in Urine and Hexachlorbenzene in Water, Applying theRegression Triplet Procedure on Chromatographic Data
Popis výsledku v původním jazyce
A method for the determination of 1-hydroxypyrene in urine and hexychlorbenzene in water applying the regression triplet in the calibration procedure of chromatographic data has been applied using the program QCEXPERT. The detection limit and quantification limit are currently calculated on the basis of the standard deviation of replicate analyses at a single concentration. However, since the standard deviation depends on concentration, these single concentration techniques result in limits that are directly dependent on spiking concentration. A more rigorous approach requires at first careful attention to the three components of the regression triplet (data, model, method), examining (a) the data quality of the proposed model; (b) the model quality; (c) the LS method to be used for a fulfilment of all least squares assumptions. On HPLC determination of 1-hydroxypyrene in urine and gas chromatography analysis of hexachlorbenzene in water, this paper describes the effects of deviations
Název v anglickém jazyce
Precision Limits and Interval Estimation in the Calibration of 1-hydroxypyrene in Urine and Hexachlorbenzene in Water, Applying theRegression Triplet Procedure on Chromatographic Data
Popis výsledku anglicky
A method for the determination of 1-hydroxypyrene in urine and hexychlorbenzene in water applying the regression triplet in the calibration procedure of chromatographic data has been applied using the program QCEXPERT. The detection limit and quantification limit are currently calculated on the basis of the standard deviation of replicate analyses at a single concentration. However, since the standard deviation depends on concentration, these single concentration techniques result in limits that are directly dependent on spiking concentration. A more rigorous approach requires at first careful attention to the three components of the regression triplet (data, model, method), examining (a) the data quality of the proposed model; (b) the model quality; (c) the LS method to be used for a fulfilment of all least squares assumptions. On HPLC determination of 1-hydroxypyrene in urine and gas chromatography analysis of hexachlorbenzene in water, this paper describes the effects of deviations
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NR9055" target="_blank" >NR9055: VLIV KOUŘENÍ A JEHO ODVYKÁNÍ NA ENDOKRINNÍ SYSTÉM</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical and Bioanalytical Chemistry
ISSN
1618-2642
e-ISSN
—
Svazek periodika
390
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
12
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—