Determination of pyridoxal, pyridoxal 5'-phosphate and 4-pyridoxic acid in plasma of selected groups of the patients with a view to proper sample preparation using HPLC with fluorescence detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F09%3A00008565" target="_blank" >RIV/00216275:25310/09:00008565 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of pyridoxal, pyridoxal 5'-phosphate and 4-pyridoxic acid in plasma of selected groups of the patients with a view to proper sample preparation using HPLC with fluorescence detection
Popis výsledku v původním jazyce
A method for the measurement of pyridoxal, pyridoxal 5'-phosphate and 4-pyridoxic acid using a high-performance liquid chromatography with fluorescence detection with regard to stability and recovery is described. For the separation, a reverse phase column LiChroCart 125-4, Purospher RP-18e, 5 um, was used. The mixture of ethanol and 25 mmol/L Na2HPO4 (7:93, v/v), pH 6.0 was used as a mobile phase. The analytical performance of this method is satisfactory: the intra-assay and inter-assay coefficients ofvariation were below 10%. Quantitative recoveries from spiked plasma samples were at intervals 93.0-101.8%, except for pyridoxal (82.5-98.8%). The limit of detection was 1.0 nmol/L for pyridoxal 5'-phosphate, 0.7 nmol/L for 4-pyridoxic acid and 1.1 nmol/L for pyridoxal. The preliminary reference range of pyridoxal 5'-phosphate, pyridoxal and 4-pyridoxic acid in a group of blood donors are 42.0-75.6 nmol/L, 2.6-12.8 nmol/L and 16.2-33.0 nmol/L, respectively.
Název v anglickém jazyce
Determination of pyridoxal, pyridoxal 5'-phosphate and 4-pyridoxic acid in plasma of selected groups of the patients with a view to proper sample preparation using HPLC with fluorescence detection
Popis výsledku anglicky
A method for the measurement of pyridoxal, pyridoxal 5'-phosphate and 4-pyridoxic acid using a high-performance liquid chromatography with fluorescence detection with regard to stability and recovery is described. For the separation, a reverse phase column LiChroCart 125-4, Purospher RP-18e, 5 um, was used. The mixture of ethanol and 25 mmol/L Na2HPO4 (7:93, v/v), pH 6.0 was used as a mobile phase. The analytical performance of this method is satisfactory: the intra-assay and inter-assay coefficients ofvariation were below 10%. Quantitative recoveries from spiked plasma samples were at intervals 93.0-101.8%, except for pyridoxal (82.5-98.8%). The limit of detection was 1.0 nmol/L for pyridoxal 5'-phosphate, 0.7 nmol/L for 4-pyridoxic acid and 1.1 nmol/L for pyridoxal. The preliminary reference range of pyridoxal 5'-phosphate, pyridoxal and 4-pyridoxic acid in a group of blood donors are 42.0-75.6 nmol/L, 2.6-12.8 nmol/L and 16.2-33.0 nmol/L, respectively.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scientific Papers of the University of Pardubice, Series A
ISSN
1211-5541
e-ISSN
—
Svazek periodika
15
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
13
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—