Numerical Error Analysis of Mass Transfer Measurements in a Continuous Dialyzer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F09%3A00008599" target="_blank" >RIV/00216275:25310/09:00008599 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Numerical Error Analysis of Mass Transfer Measurements in a Continuous Dialyzer
Popis výsledku v původním jazyce
The overall dialysis coefficient is a basic characteristic of a continuous dialyzer. Its determination is based on the measurement of concentrations and volumetric liquid flow rates of the streams entering and leaving the dialyzer -generally, all these parameters can be loaded with an experimental error. The paper is focused on the transformation of these errors into the final results. Using the generated precise experimental data, small random errors have been introduced into them and the effect of these errors upon the overall dialysis coefficient has been evaluated. The error analysis has proved that large errors of the overall dialysis coefficient can be expected if low volumetric liquid flow rate and intensive mass transfer exist. Moreover, the effect of errors of input parameters can be eliminated to a large extent using reconciled experimental data measured.
Název v anglickém jazyce
Numerical Error Analysis of Mass Transfer Measurements in a Continuous Dialyzer
Popis výsledku anglicky
The overall dialysis coefficient is a basic characteristic of a continuous dialyzer. Its determination is based on the measurement of concentrations and volumetric liquid flow rates of the streams entering and leaving the dialyzer -generally, all these parameters can be loaded with an experimental error. The paper is focused on the transformation of these errors into the final results. Using the generated precise experimental data, small random errors have been introduced into them and the effect of these errors upon the overall dialysis coefficient has been evaluated. The error analysis has proved that large errors of the overall dialysis coefficient can be expected if low volumetric liquid flow rate and intensive mass transfer exist. Moreover, the effect of errors of input parameters can be eliminated to a large extent using reconciled experimental data measured.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Desalination
ISSN
0011-9164
e-ISSN
—
Svazek periodika
239
Číslo periodika v rámci svazku
1-3
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
9
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—