Numerical error analysis of mass transfer measurements in batch dialyzer. Effect of concentration errors upon overall dialysis coefficient
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F09%3A00008604" target="_blank" >RIV/00216275:25310/09:00008604 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Numerical error analysis of mass transfer measurements in batch dialyzer. Effect of concentration errors upon overall dialysis coefficient
Popis výsledku v původním jazyce
The overall dialysis coefficient, which is the basic transport characteristic of a dialysis process, can easily be determined from experimental data obtained in a two-compartment dialysis cell. Here, the volume changes and the concentrations of componentin both the compartments are recorded as functions of time. Generally, all these input quantities can be loaded with an experimental error. The paper deals with the transformation of these errors into the final results under the conditions of constant liquid volumes in both the compartments of the dialyzer. Using the generated precise experimental data, small random errors have been introduced into them and the effect of these errors upon the overall dialysis coefficient has been evaluated. The error analysis has proved that the unfavourable effect of the input quantities is dependent upon intensity of mass transfer. Moreover, in some cases the effect of the input quantities can be eliminated to a some extent using reconciled experimen
Název v anglickém jazyce
Numerical error analysis of mass transfer measurements in batch dialyzer. Effect of concentration errors upon overall dialysis coefficient
Popis výsledku anglicky
The overall dialysis coefficient, which is the basic transport characteristic of a dialysis process, can easily be determined from experimental data obtained in a two-compartment dialysis cell. Here, the volume changes and the concentrations of componentin both the compartments are recorded as functions of time. Generally, all these input quantities can be loaded with an experimental error. The paper deals with the transformation of these errors into the final results under the conditions of constant liquid volumes in both the compartments of the dialyzer. Using the generated precise experimental data, small random errors have been introduced into them and the effect of these errors upon the overall dialysis coefficient has been evaluated. The error analysis has proved that the unfavourable effect of the input quantities is dependent upon intensity of mass transfer. Moreover, in some cases the effect of the input quantities can be eliminated to a some extent using reconciled experimen
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 36th International Conference of Slovak Society of Chemical Engineering
ISBN
978-80-227-3072-3
ISSN
—
e-ISSN
—
Počet stran výsledku
13
Strana od-do
—
Název nakladatele
Slovak Society of Chemical Engineering
Místo vydání
Bratislava
Místo konání akce
Tatranské Matliare, SK
Datum konání akce
29. 5. 2009
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—