Polymethacrylate Monolithic and Hybrid Particle-Monolithic Columns for Reversed-Phase and Hydrophilic Interaction Capillary Liquid Chromatography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F10%3A39882387" target="_blank" >RIV/00216275:25310/10:39882387 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68081715:_____/10:00335333
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Polymethacrylate Monolithic and Hybrid Particle-Monolithic Columns for Reversed-Phase and Hydrophilic Interaction Capillary Liquid Chromatography
Popis výsledku v původním jazyce
We prepared hybrid particle-monolithic polymethacrylate columns for micro-HPLC by in situ polymerization in fused silica capillaries pre-packed with 3-5m C18 and aminopropyl silica bonded particles, using polymerization mixtures based on laurylmethacrylate-ethylene dimethacrylate (co)polymers for the reversed-phase (RP) mode and [2-(methacryloyloxy)ethyl]-dimethyl-(3-sulfopropyl) zwitterionic (co)polymers for the hydrophilic interaction (HILIC) mode. The hybrid particle-monolithic columns showed reducedporosity and hold-up volumes, approximately 2-2.5 times lower in comparison to the pure monolithic columns prepared in the whole volume of empty capillaries. The elution volumes of sample compounds are also generally lower in comparison to packed or pure monolithic columns. The efficiency and permeability of the hybrid columns are intermediate in between the properties of the reference pure monolithic and particle-packed columns.
Název v anglickém jazyce
Polymethacrylate Monolithic and Hybrid Particle-Monolithic Columns for Reversed-Phase and Hydrophilic Interaction Capillary Liquid Chromatography
Popis výsledku anglicky
We prepared hybrid particle-monolithic polymethacrylate columns for micro-HPLC by in situ polymerization in fused silica capillaries pre-packed with 3-5m C18 and aminopropyl silica bonded particles, using polymerization mixtures based on laurylmethacrylate-ethylene dimethacrylate (co)polymers for the reversed-phase (RP) mode and [2-(methacryloyloxy)ethyl]-dimethyl-(3-sulfopropyl) zwitterionic (co)polymers for the hydrophilic interaction (HILIC) mode. The hybrid particle-monolithic columns showed reducedporosity and hold-up volumes, approximately 2-2.5 times lower in comparison to the pure monolithic columns prepared in the whole volume of empty capillaries. The elution volumes of sample compounds are also generally lower in comparison to packed or pure monolithic columns. The efficiency and permeability of the hybrid columns are intermediate in between the properties of the reference pure monolithic and particle-packed columns.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA203%2F08%2F1536" target="_blank" >GA203/08/1536: Progresívní metody v chemické, potravinářské a klinické analýze</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
—
Svazek periodika
1217
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
12
Strana od-do
—
Kód UT WoS článku
000273623100004
EID výsledku v databázi Scopus
—