Determination of 2-Ethylhexyl Nitrate in Diesel Fuel
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F11%3A39892562" target="_blank" >RIV/00216275:25310/11:39892562 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1002/jssc.201100137" target="_blank" >http://dx.doi.org/10.1002/jssc.201100137</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jssc.201100137" target="_blank" >10.1002/jssc.201100137</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of 2-Ethylhexyl Nitrate in Diesel Fuel
Popis výsledku v původním jazyce
The aim of this study was to develop and validate fast and easily applicable GC/MS assay for the quantification of the substance that increases cetane number in diesel fuel (2-ethylhexylnitrate, 2-EHN). These requirements were fulfilled best by a headspace GC-MS assay with negative chemical ionization with methane (HS-GC/MS). Chromatographic separation is achieved using a DB5-MS capillary column after the addition of known amount of internal standard (o-nitrotoluene). The limit of detection was 0.009% v/v for 2-EHN and the limit of quantification was 0.03% v/v. The HS-GC/MS method was applied for the quantification of cetane improver in spiked diesel fuel and real diesel fuel. The method is linear over the studied range (0.03-0.3%, v/v), with satisfactory intra-and inter-assay precision, and the relative standard deviations are lower than 10%.
Název v anglickém jazyce
Determination of 2-Ethylhexyl Nitrate in Diesel Fuel
Popis výsledku anglicky
The aim of this study was to develop and validate fast and easily applicable GC/MS assay for the quantification of the substance that increases cetane number in diesel fuel (2-ethylhexylnitrate, 2-EHN). These requirements were fulfilled best by a headspace GC-MS assay with negative chemical ionization with methane (HS-GC/MS). Chromatographic separation is achieved using a DB5-MS capillary column after the addition of known amount of internal standard (o-nitrotoluene). The limit of detection was 0.009% v/v for 2-EHN and the limit of quantification was 0.03% v/v. The HS-GC/MS method was applied for the quantification of cetane improver in spiked diesel fuel and real diesel fuel. The method is linear over the studied range (0.03-0.3%, v/v), with satisfactory intra-and inter-assay precision, and the relative standard deviations are lower than 10%.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Separation Science
ISSN
1615-9306
e-ISSN
—
Svazek periodika
34
Číslo periodika v rámci svazku
14
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
5
Strana od-do
1664-1668
Kód UT WoS článku
000293588900005