Comments to Electroanalytical Procedures with Antimony-Based Electrodes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F11%3A39892730" target="_blank" >RIV/00216275:25310/11:39892730 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comments to Electroanalytical Procedures with Antimony-Based Electrodes
Popis výsledku v původním jazyce
Antimony electrodes belong to the oldest ones in potentiometric acid-base titrations and pH measurements. (known since 1923 when introduced). The first attempt to apply an antimony-based film electrode in anodic stripping voltammetry (2004) was not completely successful because of unsuitable buffer choice. Recently (2007), it has been shown that such electrodes need to be applied in highly acidic solutions of hydrochloric acid (pH { 2). On the contrary to other metal films (Hg, Bi), products of the Sb film reoxidations are insoluble in such media and thus, it can be used in much wider potential window limited by hydrogen evolution on the catodic and chlorine evolution on the anodic sides. In addition to possible application of Sb-based electrodes to determine some heavy metals deposited and reoxidized at negative potentials, this fact allowed to elaborate new procedures for anodic stripping determination of Hg(II), Cu(II), and Bi(III). In these experiments, a catalytic effect of the pr
Název v anglickém jazyce
Comments to Electroanalytical Procedures with Antimony-Based Electrodes
Popis výsledku anglicky
Antimony electrodes belong to the oldest ones in potentiometric acid-base titrations and pH measurements. (known since 1923 when introduced). The first attempt to apply an antimony-based film electrode in anodic stripping voltammetry (2004) was not completely successful because of unsuitable buffer choice. Recently (2007), it has been shown that such electrodes need to be applied in highly acidic solutions of hydrochloric acid (pH { 2). On the contrary to other metal films (Hg, Bi), products of the Sb film reoxidations are insoluble in such media and thus, it can be used in much wider potential window limited by hydrogen evolution on the catodic and chlorine evolution on the anodic sides. In addition to possible application of Sb-based electrodes to determine some heavy metals deposited and reoxidized at negative potentials, this fact allowed to elaborate new procedures for anodic stripping determination of Hg(II), Cu(II), and Bi(III). In these experiments, a catalytic effect of the pr
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LC06035" target="_blank" >LC06035: Centrum biofyzikální chemie, bioelektrochemie a bioanalýzy. Nové nástroje pro genomiku, proteomiku a biomedicínu.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
ISEAC-WS-2011: ISEAC International Symposium cum Workshop on Electrochemistry
ISBN
978-81-901950-4-1
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
37-44
Název nakladatele
Indian Society of ElectroAnalytical Chemistry
Místo vydání
Mumbai
Místo konání akce
Dona Paula
Datum konání akce
7. 12. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—