O-TOF-ICP-MS Analysis of Rare Earth Elements, Noble Elements, Uranium and Thorium in River-relating Species
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F12%3A39881709" target="_blank" >RIV/00216275:25310/12:39881709 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1080/03067310903582382" target="_blank" >http://dx.doi.org/10.1080/03067310903582382</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/03067310903582382" target="_blank" >10.1080/03067310903582382</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
O-TOF-ICP-MS Analysis of Rare Earth Elements, Noble Elements, Uranium and Thorium in River-relating Species
Popis výsledku v původním jazyce
The determination of rare earth elements (REEs), Au, Pt, Ir, Pd, Th and U in various river species was performed by the orthogonal time-of-flight inductively coupled plasma mass spectrometry (o-TOF-ICP-MS). The method working conditions were optimised inorder to minimise the presence and possible spectral interferences of oxides. Ratios MO+/M+ as well as interference of light REE and Ba oxides/hydroxides with high REEs were evaluated and confirmed to be insignificant. Using the internal standard Re, non-spectral matrix effects (originally decreasing of intensities up to 15 %) were overcome and recoveries were found from 92 to 105 % for all matrices analysed. For solutions, limits of detection (3sigma) were 0.14 - 0.82 for REEs, Th, U and Y, 1.18 for La, 4.3 - 5.6 for Au, Pt, Ir and Pd 11 for Sc (all in ng L-1). The Principal component analysis was used for classification of samples according to their places of origin successfully. The o-TOF-ICP-MS was proved to be a very sensitive and
Název v anglickém jazyce
O-TOF-ICP-MS Analysis of Rare Earth Elements, Noble Elements, Uranium and Thorium in River-relating Species
Popis výsledku anglicky
The determination of rare earth elements (REEs), Au, Pt, Ir, Pd, Th and U in various river species was performed by the orthogonal time-of-flight inductively coupled plasma mass spectrometry (o-TOF-ICP-MS). The method working conditions were optimised inorder to minimise the presence and possible spectral interferences of oxides. Ratios MO+/M+ as well as interference of light REE and Ba oxides/hydroxides with high REEs were evaluated and confirmed to be insignificant. Using the internal standard Re, non-spectral matrix effects (originally decreasing of intensities up to 15 %) were overcome and recoveries were found from 92 to 105 % for all matrices analysed. For solutions, limits of detection (3sigma) were 0.14 - 0.82 for REEs, Th, U and Y, 1.18 for La, 4.3 - 5.6 for Au, Pt, Ir and Pd 11 for Sc (all in ng L-1). The Principal component analysis was used for classification of samples according to their places of origin successfully. The o-TOF-ICP-MS was proved to be a very sensitive and
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Environmental Analytical Chemistry
ISSN
0306-7319
e-ISSN
—
Svazek periodika
92
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
620-635
Kód UT WoS článku
000301870900010
EID výsledku v databázi Scopus
—