Voltammetric Determination of Linuron Herbi-cide Using a Tricresyl Phosphate-Based Carbon Paste Electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F12%3A39895284" target="_blank" >RIV/00216275:25310/12:39895284 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.3390/s120100148" target="_blank" >http://dx.doi.org/10.3390/s120100148</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/s120100148" target="_blank" >10.3390/s120100148</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric Determination of Linuron Herbi-cide Using a Tricresyl Phosphate-Based Carbon Paste Electrode
Popis výsledku v původním jazyce
This paper summarises the results of voltammetric studies on the herbicide 3-(3,4-dichlorophenyl)-1-methoxy-1-methylurea (Linuron), using a carbon paste electrode containing tricresyl phosphate (TCP-CPE) as liquid binder. The principal experimental conditions, such as the pH effect, investigated in Britton-Robinson buffer solutions (pH 2.0-7.0), the peak characteristics for the analyte of interest, or instrumental parameters for the differential pulse voltammetric mode were optimized for the method. Asfound out, the best electroanalytical performance of the TCP-CPE was achieved at pH 2.0, whereby the oxidation peak of Linuron appeared at ca. +1.3 V vs. SCE. The analytical procedure developed offers good linearity in the concentration range of 1.25-44.20 mýg mL?1 (1.77 x 10?4-5.05 x 10?6 mol L?1), showing --- for the first time --- the applicability of the TCP-CPE for anodic oxidations in direct voltammetry (without accumulation). The method was then verified by determining Linuron in
Název v anglickém jazyce
Voltammetric Determination of Linuron Herbi-cide Using a Tricresyl Phosphate-Based Carbon Paste Electrode
Popis výsledku anglicky
This paper summarises the results of voltammetric studies on the herbicide 3-(3,4-dichlorophenyl)-1-methoxy-1-methylurea (Linuron), using a carbon paste electrode containing tricresyl phosphate (TCP-CPE) as liquid binder. The principal experimental conditions, such as the pH effect, investigated in Britton-Robinson buffer solutions (pH 2.0-7.0), the peak characteristics for the analyte of interest, or instrumental parameters for the differential pulse voltammetric mode were optimized for the method. Asfound out, the best electroanalytical performance of the TCP-CPE was achieved at pH 2.0, whereby the oxidation peak of Linuron appeared at ca. +1.3 V vs. SCE. The analytical procedure developed offers good linearity in the concentration range of 1.25-44.20 mýg mL?1 (1.77 x 10?4-5.05 x 10?6 mol L?1), showing --- for the first time --- the applicability of the TCP-CPE for anodic oxidations in direct voltammetry (without accumulation). The method was then verified by determining Linuron in
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensors
ISSN
1424-8220
e-ISSN
—
Svazek periodika
12
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
14
Strana od-do
148-161
Kód UT WoS článku
000299537100007
EID výsledku v databázi Scopus
—