Determination of epinephrine, norepinephrine and dopamine in human urine using high-performance liquid chromatography with coulometric detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F13%3A39896727" target="_blank" >RIV/00216275:25310/13:39896727 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of epinephrine, norepinephrine and dopamine in human urine using high-performance liquid chromatography with coulometric detection
Popis výsledku v původním jazyce
A relative simple method for the simultaneous determination of epinephrine, norepinephrine and dopamine in urine is presented. We have used a high-performance liquid chromatography (HPLC) with coulometric electrochemical detection. Urine samples pretreatment by a solid-phase extraction were injected directly into the HPLC system and were eluted isocratically on a Discovery HS C18, 250 x 4 mm i.d., 5 um, analytical column. The analytical performance of this method is satisfactory: the intra-assay and inter-assay coefficients of variation were below 10%. Quantitative recoveries from spiked urine samples were at intervals 78.2-88.0% for epinephrine, 80.0-93.0% for norepinephrine, and 96.4-107.2% for dopamine. The linear range is 2-200 ug l-1, with a detection limit of 0.6 ug l-1 (signal-to-noise ratio = 3) for epinephrine, 5-500 ug l-1, with a detection limit of 1.5 ug l-1 for norepinephrine, and 20-2000 ug l-1, with a detection limit of 6 ug l-1 for dopamine.
Název v anglickém jazyce
Determination of epinephrine, norepinephrine and dopamine in human urine using high-performance liquid chromatography with coulometric detection
Popis výsledku anglicky
A relative simple method for the simultaneous determination of epinephrine, norepinephrine and dopamine in urine is presented. We have used a high-performance liquid chromatography (HPLC) with coulometric electrochemical detection. Urine samples pretreatment by a solid-phase extraction were injected directly into the HPLC system and were eluted isocratically on a Discovery HS C18, 250 x 4 mm i.d., 5 um, analytical column. The analytical performance of this method is satisfactory: the intra-assay and inter-assay coefficients of variation were below 10%. Quantitative recoveries from spiked urine samples were at intervals 78.2-88.0% for epinephrine, 80.0-93.0% for norepinephrine, and 96.4-107.2% for dopamine. The linear range is 2-200 ug l-1, with a detection limit of 0.6 ug l-1 (signal-to-noise ratio = 3) for epinephrine, 5-500 ug l-1, with a detection limit of 1.5 ug l-1 for norepinephrine, and 20-2000 ug l-1, with a detection limit of 6 ug l-1 for dopamine.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scientific Papers of the University of Pardubice, Series A, Faculty of Chemical Technology
ISSN
1211-5541
e-ISSN
—
Svazek periodika
19
Číslo periodika v rámci svazku
prosinec
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
14
Strana od-do
25-38
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—