Voltammetric analysis of herbicide picloram on solid electrodes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F14%3A39898018" target="_blank" >RIV/00216275:25310/14:39898018 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric analysis of herbicide picloram on solid electrodes
Popis výsledku v původním jazyce
Voltammetric behaviour of pyridine herbicide picloram (PCR) was investigated using two types of relatively new and perspective electrode materials: silver solid amalgam and boron-doped diamond. Various methods like cyclic voltammetry, linear sweep voltammetry and differential pulse voltammetry were examined. It was found, that PCR provided only one signal measurable on both tested working electrodes in an acidic medium. Its electrochemical reduction could be recorded on mercury meniscus modified silversolid amalgam electrode and different oxidation signal was measured on bare boron-doped diamond film electrode. Parameters of differential pulse voltammetry were optimized and the low limits of detection (LD(m-AgSAE) = 3.5x10-8 mol L-1 and LD(BDDFE) = 7.0x10-8 mol L-1) were reached.
Název v anglickém jazyce
Voltammetric analysis of herbicide picloram on solid electrodes
Popis výsledku anglicky
Voltammetric behaviour of pyridine herbicide picloram (PCR) was investigated using two types of relatively new and perspective electrode materials: silver solid amalgam and boron-doped diamond. Various methods like cyclic voltammetry, linear sweep voltammetry and differential pulse voltammetry were examined. It was found, that PCR provided only one signal measurable on both tested working electrodes in an acidic medium. Its electrochemical reduction could be recorded on mercury meniscus modified silversolid amalgam electrode and different oxidation signal was measured on bare boron-doped diamond film electrode. Parameters of differential pulse voltammetry were optimized and the low limits of detection (LD(m-AgSAE) = 3.5x10-8 mol L-1 and LD(BDDFE) = 7.0x10-8 mol L-1) were reached.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.30.0021" target="_blank" >EE2.3.30.0021: Posílení excelentních týmů výzkumu a vývoje na Univerzitě Pardubice</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník přednášek mezinárodní odborné konference XXXIV. Moderní elektrochemické metody
ISBN
978-80-905221-2-1
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
9-13
Název nakladatele
BEST Servis
Místo vydání
Ústí nad Labem
Místo konání akce
Jetřichovice
Datum konání akce
19. 5. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—