Developments in the preparation of organic polymer monoliths for the separation of smal molecules
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F14%3A39898141" target="_blank" >RIV/00216275:25310/14:39898141 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Developments in the preparation of organic polymer monoliths for the separation of smal molecules
Popis výsledku v původním jazyce
Organic polymer monoliths are mainly used to separate macromolecules in gradient elution liquid chromatography (LC) because of their favorable porous structure. The main reason for the poor behavior of organic polymer monoliths when separating small molecules isocratically was attributed to the lack of small pores with a stagnant mobile phase, and the resulting low surface area. Recent efforts have improved the separation power of organic polymer monoliths for small molecules, offering column efficiencies up to 50,000-80,000 plates/m. This review describes recent developments in the preparation of organic polymer monoliths suitable for the separation of small molecules in the isocratic mode, and discusses the main factors affecting the column efficiency.
Název v anglickém jazyce
Developments in the preparation of organic polymer monoliths for the separation of smal molecules
Popis výsledku anglicky
Organic polymer monoliths are mainly used to separate macromolecules in gradient elution liquid chromatography (LC) because of their favorable porous structure. The main reason for the poor behavior of organic polymer monoliths when separating small molecules isocratically was attributed to the lack of small pores with a stagnant mobile phase, and the resulting low surface area. Recent efforts have improved the separation power of organic polymer monoliths for small molecules, offering column efficiencies up to 50,000-80,000 plates/m. This review describes recent developments in the preparation of organic polymer monoliths suitable for the separation of small molecules in the isocratic mode, and discusses the main factors affecting the column efficiency.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
LC/GC North America
ISSN
1527-5949
e-ISSN
—
Svazek periodika
32
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
576-584
Kód UT WoS článku
000340810500007
EID výsledku v databázi Scopus
—