Lead Film Electrode Prepared with the Use of a Reversibly Deposited Mediator Metal in Adsorptive Stripping Voltammetry of Nickel
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F14%3A39898304" target="_blank" >RIV/00216275:25310/14:39898304 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elan.201400263" target="_blank" >http://dx.doi.org/10.1002/elan.201400263</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201400263" target="_blank" >10.1002/elan.201400263</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Lead Film Electrode Prepared with the Use of a Reversibly Deposited Mediator Metal in Adsorptive Stripping Voltammetry of Nickel
Popis výsledku v původním jazyce
The paper presents the first report on application of a "hybrid" lead film electrode for the adsorptive stripping voltammetric determination of Ni(II) in the presence of nioxime as a complexing agent. The strategy to create a "hybrid" electrode is basedon the combination of ex situ and in situ plating methods and the use of a reversibly deposited mediator metal (Zn) for the lead film formation. The surface morphology of a new sensor was characterized by atomic force microscopy. The detection limit forNi(II) obtained at 120 s of accumulation time was 3.9 x 10(-11) mol L(-1). The proposed method was validated for the determination of nickel in water certified reference materials with good results.
Název v anglickém jazyce
Lead Film Electrode Prepared with the Use of a Reversibly Deposited Mediator Metal in Adsorptive Stripping Voltammetry of Nickel
Popis výsledku anglicky
The paper presents the first report on application of a "hybrid" lead film electrode for the adsorptive stripping voltammetric determination of Ni(II) in the presence of nioxime as a complexing agent. The strategy to create a "hybrid" electrode is basedon the combination of ex situ and in situ plating methods and the use of a reversibly deposited mediator metal (Zn) for the lead film formation. The surface morphology of a new sensor was characterized by atomic force microscopy. The detection limit forNi(II) obtained at 120 s of accumulation time was 3.9 x 10(-11) mol L(-1). The proposed method was validated for the determination of nickel in water certified reference materials with good results.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
2049-2056
Kód UT WoS článku
000343926700024
EID výsledku v databázi Scopus
—