Concerning the Shock Sensitivity of Cyclic Nitramines Incorporated into a Polyisobutylene Matrix
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F14%3A39898595" target="_blank" >RIV/00216275:25310/14:39898595 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Concerning the Shock Sensitivity of Cyclic Nitramines Incorporated into a Polyisobutylene Matrix
Popis výsledku v původním jazyce
Two types of plastic bonded explosives (PBXs) based on e-2,4,6,8,10,12-hexanitro-2,4,6,8,10,12-hexaazaisowurtzitane (e-HNIW, CL-20), and PBXs based on 1,3,5-trinitro-1,3,5-triazinane (RDX), b-1,3,4,7-tetranitro-1,3,5,7-tetrazocane (b-HMX) and cis-1,3,4,6-tetranitro-octahydroimidazo-[4,5-d]imidazole (bicyclo-HMX, BCHMX) were prepd. using a polyisobutylene binder, i.e. a C4 matrix. One version of the e-HNIW PBX is a product with reduced sensitivity (RS-e-HNIW). All these PBXs were tested using the Small Scale Gap Test according to STANAG 4488. The results on the PBXs with RDX, b-HMX and BCHMX correspond to the impact sensitivities of the original cryst. nitramines. This is not entirely valid for e-HNIW. In other words, PBXs with RS-e-HNIW cannot achieveas low a shock sensitivity as would be expected from the differences obtained from the impact sensitivities between RDX, b-HMX and BCHMX, on the one hand, and RS-e-HNIW on the other. It is shown that the morphological stability of RS-e-HN
Název v anglickém jazyce
Concerning the Shock Sensitivity of Cyclic Nitramines Incorporated into a Polyisobutylene Matrix
Popis výsledku anglicky
Two types of plastic bonded explosives (PBXs) based on e-2,4,6,8,10,12-hexanitro-2,4,6,8,10,12-hexaazaisowurtzitane (e-HNIW, CL-20), and PBXs based on 1,3,5-trinitro-1,3,5-triazinane (RDX), b-1,3,4,7-tetranitro-1,3,5,7-tetrazocane (b-HMX) and cis-1,3,4,6-tetranitro-octahydroimidazo-[4,5-d]imidazole (bicyclo-HMX, BCHMX) were prepd. using a polyisobutylene binder, i.e. a C4 matrix. One version of the e-HNIW PBX is a product with reduced sensitivity (RS-e-HNIW). All these PBXs were tested using the Small Scale Gap Test according to STANAG 4488. The results on the PBXs with RDX, b-HMX and BCHMX correspond to the impact sensitivities of the original cryst. nitramines. This is not entirely valid for e-HNIW. In other words, PBXs with RS-e-HNIW cannot achieveas low a shock sensitivity as would be expected from the differences obtained from the impact sensitivities between RDX, b-HMX and BCHMX, on the one hand, and RS-e-HNIW on the other. It is shown that the morphological stability of RS-e-HN
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Central European Journal of Energetic Materials
ISSN
1733-7178
e-ISSN
—
Svazek periodika
11
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
17
Strana od-do
219-235
Kód UT WoS článku
000340082600004
EID výsledku v databázi Scopus
—