Lab-made Sensors Based on Boron-doped Diamond for Determination of Herbicide Linuron
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F15%3A39900166" target="_blank" >RIV/00216275:25310/15:39900166 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388955:_____/15:00444485
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Lab-made Sensors Based on Boron-doped Diamond for Determination of Herbicide Linuron
Popis výsledku v původním jazyce
Voltammetric behaviour of substituted urea herbicide linuron (LIN) was investigated using two types of boron-doped diamond electrodes (BDDE): commercial BDDE and lab-made sensors based on boron-doped diamond (LM-BDDE). Various methods like cyclic voltammetry (CV), direct current voltammetry (DCV) and differential pulse voltammetry (DPV) were examined. It was found that LIN provides one oxidation peak using all of the tested working electrodes and the highest current response was recorded in the acidic media. Thus, Britton-Robinson (B-R) buffer of pH 2 was used as a supporting electrolyte. Parameters of DPV were optimized and the low limits of detection (LOD) were reached 1.41x10MINUS SIGN 7 M for commercial boron-doped diamond electrode and 8.81x10MINUS SIGN 9 M, respectively, which represents the lowest LOD obtained for lab-made boron-doped diamond electrodes.
Název v anglickém jazyce
Lab-made Sensors Based on Boron-doped Diamond for Determination of Herbicide Linuron
Popis výsledku anglicky
Voltammetric behaviour of substituted urea herbicide linuron (LIN) was investigated using two types of boron-doped diamond electrodes (BDDE): commercial BDDE and lab-made sensors based on boron-doped diamond (LM-BDDE). Various methods like cyclic voltammetry (CV), direct current voltammetry (DCV) and differential pulse voltammetry (DPV) were examined. It was found that LIN provides one oxidation peak using all of the tested working electrodes and the highest current response was recorded in the acidic media. Thus, Britton-Robinson (B-R) buffer of pH 2 was used as a supporting electrolyte. Parameters of DPV were optimized and the low limits of detection (LOD) were reached 1.41x10MINUS SIGN 7 M for commercial boron-doped diamond electrode and 8.81x10MINUS SIGN 9 M, respectively, which represents the lowest LOD obtained for lab-made boron-doped diamond electrodes.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.30.0021" target="_blank" >EE2.3.30.0021: Posílení excelentních týmů výzkumu a vývoje na Univerzitě Pardubice</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XXXV Moderní elektrochemické metody
ISBN
978-80-905221-3-8
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
236-240
Název nakladatele
BEST Servis
Místo vydání
Ústí nad Labem
Místo konání akce
Jetřichovice
Datum konání akce
18. 5. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000358792900053