The Effects of the Column Length on the Efficiency of Capillary Zwitterionic Organic Polymer Monolithic Columns in HILIC Chromatography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F15%3A39900316" target="_blank" >RIV/00216275:25310/15:39900316 - isvavai.cz</a>
Výsledek na webu
<a href="http://apps.webofknowledge.com/full_record.do?product=UA&search_mode=GeneralSearch&qid=3&SID=U2wX1qdelgCSs7OzriD&page=1&doc=1" target="_blank" >http://apps.webofknowledge.com/full_record.do?product=UA&search_mode=GeneralSearch&qid=3&SID=U2wX1qdelgCSs7OzriD&page=1&doc=1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10337-015-2848-4" target="_blank" >10.1007/s10337-015-2848-4</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Effects of the Column Length on the Efficiency of Capillary Zwitterionic Organic Polymer Monolithic Columns in HILIC Chromatography
Popis výsledku v původním jazyce
Organic polymer monolithic columns of different lengths have been prepared in 320 A mu m i.d. fused silica capillary by in situ radical polymerization of N,N-dimethyl-N-methacryloxyethyl-N-(3-sulfopropyl) ammonium betaine as a zwitterionic functional monomer and bisphenol A glycerolate dimethacrylate as a crosslinking monomer in the presence of porogenic solvents. The zwitterionic monolithic columns are intended for separations of polar compounds in hydrophilic interaction chromatography (HILIC). The effects of the capillary column length, from 115 to 175 mm, on separation efficiency, were investigated under HILIC conditions, using 95:5 acetonitrile in water as the mobile phase. The extra-column contributions to band broadening significantly decrease the efficiency (apparent height equivalent to a theoretical plate), especially for weakly retained samples, and increase with diminishing column length. The experimental height equivalents of theoretical plate, HETP, were corrected for the
Název v anglickém jazyce
The Effects of the Column Length on the Efficiency of Capillary Zwitterionic Organic Polymer Monolithic Columns in HILIC Chromatography
Popis výsledku anglicky
Organic polymer monolithic columns of different lengths have been prepared in 320 A mu m i.d. fused silica capillary by in situ radical polymerization of N,N-dimethyl-N-methacryloxyethyl-N-(3-sulfopropyl) ammonium betaine as a zwitterionic functional monomer and bisphenol A glycerolate dimethacrylate as a crosslinking monomer in the presence of porogenic solvents. The zwitterionic monolithic columns are intended for separations of polar compounds in hydrophilic interaction chromatography (HILIC). The effects of the capillary column length, from 115 to 175 mm, on separation efficiency, were investigated under HILIC conditions, using 95:5 acetonitrile in water as the mobile phase. The extra-column contributions to band broadening significantly decrease the efficiency (apparent height equivalent to a theoretical plate), especially for weakly retained samples, and increase with diminishing column length. The experimental height equivalents of theoretical plate, HETP, were corrected for the
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP206%2F12%2F0398" target="_blank" >GAP206/12/0398: Dvourozměrné separace v kapalných médiích</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chromatographia
ISSN
0009-5893
e-ISSN
—
Svazek periodika
79
Číslo periodika v rámci svazku
13-14
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
7
Strana od-do
853-859
Kód UT WoS článku
000357460300002
EID výsledku v databázi Scopus
—