Název v původním jazyce
Crystallization kinetics in Se-Te glassy system-Effect of long-term material degradation
Popis výsledku v původním jazyce
The influence of long-term laboratory-temperature degradation on the crystallization kinetics of the Se90Te10, Se80Te20 and Se70Te30 chalcogenide glasses was studied by differential scanning calorimetry. Periodical measurements during the 6 months aging period have shown that the fine Se-Te powders degraded largely, large degree of crystallinity occurred even though the materials were stored well below their glass transition temperature. The degradation increased with Te content. The defects-based residual crystallization kinetics exhibited by the fine Se-Te powders was not influenced significantly by the continuous degradation. Coarse Se-Te powders, on the other hand, exhibited only weak degradation with low amount of crystallinity occurring during the 6 months period but the crystallization kinetics of the degraded glasses changed markedly. The degraded coarse Se-Te powders have shown increased nuclei based volume-located growth of crystallites, which indicates that nucleation proceeded significantly below the glass transition; the effect increased largely with Te content.
Název v anglickém jazyce
Crystallization kinetics in Se-Te glassy system-Effect of long-term material degradation
Popis výsledku anglicky
The influence of long-term laboratory-temperature degradation on the crystallization kinetics of the Se90Te10, Se80Te20 and Se70Te30 chalcogenide glasses was studied by differential scanning calorimetry. Periodical measurements during the 6 months aging period have shown that the fine Se-Te powders degraded largely, large degree of crystallinity occurred even though the materials were stored well below their glass transition temperature. The degradation increased with Te content. The defects-based residual crystallization kinetics exhibited by the fine Se-Te powders was not influenced significantly by the continuous degradation. Coarse Se-Te powders, on the other hand, exhibited only weak degradation with low amount of crystallinity occurring during the 6 months period but the crystallization kinetics of the degraded glasses changed markedly. The degraded coarse Se-Te powders have shown increased nuclei based volume-located growth of crystallites, which indicates that nucleation proceeded significantly below the glass transition; the effect increased largely with Te content.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Thermochimica Acta
ISSN
0040-6031
e-ISSN
—
Svazek periodika
639
Číslo periodika v rámci svazku
September
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
12
Strana od-do
108-119
Kód UT WoS článku
000383006200013
EID výsledku v databázi Scopus
—