Comparison study of voltammetric behavior of muscle relaxant dantrolene sodium on silver solid amalgam and bismuth film electrodes.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F17%3A39910935" target="_blank" >RIV/00216275:25310/17:39910935 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388955:_____/17:00483312
Výsledek na webu
<a href="http://dx.doi.org/10.1155/2017/3627428" target="_blank" >http://dx.doi.org/10.1155/2017/3627428</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1155/2017/3627428" target="_blank" >10.1155/2017/3627428</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison study of voltammetric behavior of muscle relaxant dantrolene sodium on silver solid amalgam and bismuth film electrodes.
Popis výsledku v původním jazyce
Voltammetric behavior of muscle relaxant dantrolene sodium (DAN) was studied and the voltammetric methods for its determination using polished and mercury meniscus modified silver solid amalgam electrodes (p-AgSAE and m-AgSAE) as well as using bismuth film electrode (BiFE, ex situ plating on GCE) have been proposed. These working electrodes represent the most commonly used alternatives to mercury ones which come wrongfully into disfavor because of alleged toxicity of mercury. Within this work, the obtained results of DAN determination have been completed by corresponding statistical parameters and also some electrochemical characteristics of AgSAEs and BiFE were assessed, especially in comparison with the mercury electrodes.
Název v anglickém jazyce
Comparison study of voltammetric behavior of muscle relaxant dantrolene sodium on silver solid amalgam and bismuth film electrodes.
Popis výsledku anglicky
Voltammetric behavior of muscle relaxant dantrolene sodium (DAN) was studied and the voltammetric methods for its determination using polished and mercury meniscus modified silver solid amalgam electrodes (p-AgSAE and m-AgSAE) as well as using bismuth film electrode (BiFE, ex situ plating on GCE) have been proposed. These working electrodes represent the most commonly used alternatives to mercury ones which come wrongfully into disfavor because of alleged toxicity of mercury. Within this work, the obtained results of DAN determination have been completed by corresponding statistical parameters and also some electrochemical characteristics of AgSAEs and BiFE were assessed, especially in comparison with the mercury electrodes.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA17-03868S" target="_blank" >GA17-03868S: Nové metody elektrochemického sledování biologicky aktivních organických látek v environmentálních, biologických a potravinových matricích</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of analytical metohods in chemistry
ISSN
2090-8865
e-ISSN
—
Svazek periodika
2017
Číslo periodika v rámci svazku
2017
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
12
Strana od-do
"3627428-1"-"3627428-12"
Kód UT WoS článku
000411652500001
EID výsledku v databázi Scopus
—