Influence of operating parameters on the rejection of zinc ions from aqueous solution by a nanofiltration polyamide membrane
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F17%3A39911019" target="_blank" >RIV/00216275:25310/17:39911019 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of operating parameters on the rejection of zinc ions from aqueous solution by a nanofiltration polyamide membrane
Popis výsledku v původním jazyce
This work focuses on the potential use of a commercial thin-film composite polyamide nanofiltration membranes for removal of extremely polluting and toxic Zn (II) ions from wastewater. The experiments have been performed for aqueous solutions containing zinc over a wide range of concentration in batch mode with total recycle of permeate and retentate. The influence of operating conditions such as applied pressure, feed concentration, cross-flow velocity and pH was examined. Only at lower fluxes, rejection of zinc ions increases with increasing feed concentration in concentration range tested. A plateau of the observed rejection has been reached at pressure higher than 20 bar. The maximum rejection of zinc ions was 99.3% without regard to the concentration range (50–200 mg Zn/L). For evaluation of cross-flow velocity, the film model has been used. In addition, the real retention was almost independent on the feed flow rate. From the results obtained, AFC 30 membrane can be highly recommended for removing of heavy metals such as zinc from wastewater.
Název v anglickém jazyce
Influence of operating parameters on the rejection of zinc ions from aqueous solution by a nanofiltration polyamide membrane
Popis výsledku anglicky
This work focuses on the potential use of a commercial thin-film composite polyamide nanofiltration membranes for removal of extremely polluting and toxic Zn (II) ions from wastewater. The experiments have been performed for aqueous solutions containing zinc over a wide range of concentration in batch mode with total recycle of permeate and retentate. The influence of operating conditions such as applied pressure, feed concentration, cross-flow velocity and pH was examined. Only at lower fluxes, rejection of zinc ions increases with increasing feed concentration in concentration range tested. A plateau of the observed rejection has been reached at pressure higher than 20 bar. The maximum rejection of zinc ions was 99.3% without regard to the concentration range (50–200 mg Zn/L). For evaluation of cross-flow velocity, the film model has been used. In addition, the real retention was almost independent on the feed flow rate. From the results obtained, AFC 30 membrane can be highly recommended for removing of heavy metals such as zinc from wastewater.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20402 - Chemical process engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
44th International conference of SSCHE : proceedings
ISBN
978-80-89597-58-1
ISSN
—
e-ISSN
neuvedeno
Počet stran výsledku
10
Strana od-do
6-15
Název nakladatele
Slovenská spoločnosť chemického inžinierstva
Místo vydání
Bratislava
Místo konání akce
Jasná
Datum konání akce
22. 5. 2017
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—