Continuous dialysis of mixture of inorganic acids
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F17%3A39911254" target="_blank" >RIV/00216275:25310/17:39911254 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.seppur.2016.08.020" target="_blank" >http://dx.doi.org/10.1016/j.seppur.2016.08.020</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.seppur.2016.08.020" target="_blank" >10.1016/j.seppur.2016.08.020</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Continuous dialysis of mixture of inorganic acids
Popis výsledku v původním jazyce
The simultaneous transport of sulphuric and phosphoric acids through a polymeric membrane was investigated at steady state in a two-compartment counter-current dialyzer. For this purpose, an anion exchange membrane Neosepta-AFN (Astom Corporation, Tokyo, Japan) was used. This transport was quantified by four membrane mass transfer coefficients which are dependent upon the concentrations of both acids in the feed. These coefficients were determined by a two-step procedure. In the first step, the basic differential equations describing the dependences of the volumetric liquid flow rates and acid concentrations on the length coordinate in the individual compartments were numerically integrated. In the second step, an objective function was minimised to ensure the best coincidence between the experimental and calculated data.
Název v anglickém jazyce
Continuous dialysis of mixture of inorganic acids
Popis výsledku anglicky
The simultaneous transport of sulphuric and phosphoric acids through a polymeric membrane was investigated at steady state in a two-compartment counter-current dialyzer. For this purpose, an anion exchange membrane Neosepta-AFN (Astom Corporation, Tokyo, Japan) was used. This transport was quantified by four membrane mass transfer coefficients which are dependent upon the concentrations of both acids in the feed. These coefficients were determined by a two-step procedure. In the first step, the basic differential equations describing the dependences of the volumetric liquid flow rates and acid concentrations on the length coordinate in the individual compartments were numerically integrated. In the second step, an objective function was minimised to ensure the best coincidence between the experimental and calculated data.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20402 - Chemical process engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Separation and Purification Technology
ISSN
1383-5866
e-ISSN
—
Svazek periodika
172
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
277-284
Kód UT WoS článku
000385602300032
EID výsledku v databázi Scopus
—