Triclosan degradation by electro-Fenton process using electrolytic unit with titanium electrodes coated with mixed IrO2/RuO2
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F17%3A39911536" target="_blank" >RIV/00216275:25310/17:39911536 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Triclosan degradation by electro-Fenton process using electrolytic unit with titanium electrodes coated with mixed IrO2/RuO2
Popis výsledku v původním jazyce
The paper focus on the degradation of a widely used antibacterial agent triclosan (5-chloro-2-(2,4-dichlorophenoxy)phenol) by electro-Fenton process. The electrochemical process was conducted in recirculating setup by passing the reaction mixture through an electrolytic unit consisting of titanium electrodes coated with mixed iridium and ruthenium oxides. An initial triclosan concentration of 10 mg/L was used throughout. Different reaction conditions and their impact on triclosan degradation were studied such as different concentrations of added iron(II) as Fenton reagent, different concentrations of sodium sulfate electrolyte, different flow rates, current density values and different pH values. High triclosan sorption to plastic surfaces of the equipment (tubing, cells etc) was observed and this phenomenon was quantified and taken into account during calculations. About 30 – 50% of triclosan was degraded after 80 minutes of electrolytic process. The optimum conditions for electro-Fenton degradation of triclosan were: current density 24 mA/cm2, flow rate 50 ml/min, pH 4, initial concentration of iron(II) at 5 mg/l, and 2 mmol/l sodium sulfate.
Název v anglickém jazyce
Triclosan degradation by electro-Fenton process using electrolytic unit with titanium electrodes coated with mixed IrO2/RuO2
Popis výsledku anglicky
The paper focus on the degradation of a widely used antibacterial agent triclosan (5-chloro-2-(2,4-dichlorophenoxy)phenol) by electro-Fenton process. The electrochemical process was conducted in recirculating setup by passing the reaction mixture through an electrolytic unit consisting of titanium electrodes coated with mixed iridium and ruthenium oxides. An initial triclosan concentration of 10 mg/L was used throughout. Different reaction conditions and their impact on triclosan degradation were studied such as different concentrations of added iron(II) as Fenton reagent, different concentrations of sodium sulfate electrolyte, different flow rates, current density values and different pH values. High triclosan sorption to plastic surfaces of the equipment (tubing, cells etc) was observed and this phenomenon was quantified and taken into account during calculations. About 30 – 50% of triclosan was degraded after 80 minutes of electrolytic process. The optimum conditions for electro-Fenton degradation of triclosan were: current density 24 mA/cm2, flow rate 50 ml/min, pH 4, initial concentration of iron(II) at 5 mg/l, and 2 mmol/l sodium sulfate.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
10511 - Environmental sciences (social aspects to be 5.7)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Waste Forum
ISSN
1804-0195
e-ISSN
—
Svazek periodika
2017
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
9
Strana od-do
116-124
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85031100531