Tangential area-proportional baseline interpolation for complex-process DSC data - Yes or no?
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F17%3A39911960" target="_blank" >RIV/00216275:25310/17:39911960 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.tca.2017.10.011" target="_blank" >http://dx.doi.org/10.1016/j.tca.2017.10.011</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.tca.2017.10.011" target="_blank" >10.1016/j.tca.2017.10.011</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Tangential area-proportional baseline interpolation for complex-process DSC data - Yes or no?
Popis výsledku v původním jazyce
Theoretical simulations were used to evaluate distortions arising from the usage of tangential area-proportional interpolation in certain situations corresponding the specific thermokinetic background courses. In particular, the effects of different types of complex kinetic peaks (consisting of overlapping sub-processes) and different heat capacity changes associated with the given sub-processes were investigated. Performance of the tangential area-proportional baseline was evaluated in terms of the magnitude of errors arising from the consequent kinetic analysis done on the basis of isoconversional methods and multivariate kinetic analysis. Apparent activation energy and pre-exponential factor were found to be only very weakly influenced by usage of tangential area proportional interpolation in most of the commonly encountered inappropriate situations. On the other hand, the model-based parameters (kinetic model exponents or even preference of certain model) can be significantly affected by usage of tangential area-proportional interpolation without the exact knowledge of the true course of thermokinetic background. These errors increase with decreasing relative magnitude of the given sub-peak. Largest errors (up to 20%) were then associated with determination of the integral area of the kinetic peak (quantity related to the specific enthalpy of the process).
Název v anglickém jazyce
Tangential area-proportional baseline interpolation for complex-process DSC data - Yes or no?
Popis výsledku anglicky
Theoretical simulations were used to evaluate distortions arising from the usage of tangential area-proportional interpolation in certain situations corresponding the specific thermokinetic background courses. In particular, the effects of different types of complex kinetic peaks (consisting of overlapping sub-processes) and different heat capacity changes associated with the given sub-processes were investigated. Performance of the tangential area-proportional baseline was evaluated in terms of the magnitude of errors arising from the consequent kinetic analysis done on the basis of isoconversional methods and multivariate kinetic analysis. Apparent activation energy and pre-exponential factor were found to be only very weakly influenced by usage of tangential area proportional interpolation in most of the commonly encountered inappropriate situations. On the other hand, the model-based parameters (kinetic model exponents or even preference of certain model) can be significantly affected by usage of tangential area-proportional interpolation without the exact knowledge of the true course of thermokinetic background. These errors increase with decreasing relative magnitude of the given sub-peak. Largest errors (up to 20%) were then associated with determination of the integral area of the kinetic peak (quantity related to the specific enthalpy of the process).
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA17-11753S" target="_blank" >GA17-11753S: Kinetická analýza komplexních fyzikálně chemických procesů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Thermochimica Acta
ISSN
0040-6031
e-ISSN
—
Svazek periodika
658
Číslo periodika v rámci svazku
December
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
55-62
Kód UT WoS článku
000417665700008
EID výsledku v databázi Scopus
2-s2.0-85032497556