Influence of boron content on electrochemical properties of boron-doped diamond electrodes and their utilization for leucovorin determination.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F18%3A39913093" target="_blank" >RIV/00216275:25310/18:39913093 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.jelechem.2018.02.007" target="_blank" >http://dx.doi.org/10.1016/j.jelechem.2018.02.007</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jelechem.2018.02.007" target="_blank" >10.1016/j.jelechem.2018.02.007</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of boron content on electrochemical properties of boron-doped diamond electrodes and their utilization for leucovorin determination.
Popis výsledku v původním jazyce
Set of the lab-made boron-doped diamond electrodes (BDDEs) prepared with various B/C ratio (1000, 2000, 4000, 8000, 10,000, and 20,000 ppm) in the gas phase was subjected to the detailed characterization in the present paper. It was proved, that the B/C ratio influenced the electrochemical features of the working electrodes like a width of the potential window, which decreased with increasing B/C. Variations of reversibility of two redox systems (Fe(CN)63−/4− and Ru(NH3)62+/3+) depending on B/C were observed as well. The best electrochemical properties were found for BDDE with B/C 10000 ppm. Moreover, the working electrodes were tested for voltammetric analysis of leucovorin based on its oxidation. The lab-made BDDEs were applied for voltammetric analysis of the pharmaceutical preparation containing leucovorin with excellent results (recovery 97.7–103.3%, RSD5 ≤ 2.1%).
Název v anglickém jazyce
Influence of boron content on electrochemical properties of boron-doped diamond electrodes and their utilization for leucovorin determination.
Popis výsledku anglicky
Set of the lab-made boron-doped diamond electrodes (BDDEs) prepared with various B/C ratio (1000, 2000, 4000, 8000, 10,000, and 20,000 ppm) in the gas phase was subjected to the detailed characterization in the present paper. It was proved, that the B/C ratio influenced the electrochemical features of the working electrodes like a width of the potential window, which decreased with increasing B/C. Variations of reversibility of two redox systems (Fe(CN)63−/4− and Ru(NH3)62+/3+) depending on B/C were observed as well. The best electrochemical properties were found for BDDE with B/C 10000 ppm. Moreover, the working electrodes were tested for voltammetric analysis of leucovorin based on its oxidation. The lab-made BDDEs were applied for voltammetric analysis of the pharmaceutical preparation containing leucovorin with excellent results (recovery 97.7–103.3%, RSD5 ≤ 2.1%).
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA17-03868S" target="_blank" >GA17-03868S: Nové metody elektrochemického sledování biologicky aktivních organických látek v environmentálních, biologických a potravinových matricích</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Electroanalytical Chemistry
ISSN
1572-6657
e-ISSN
—
Svazek periodika
821
Číslo periodika v rámci svazku
July
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
8
Strana od-do
2-9
Kód UT WoS článku
000437818600002
EID výsledku v databázi Scopus
2-s2.0-85041506588